Endress+Hauser Proline Promass S 300
Coriolis flowmeter
- Overview +
- Comments +
Promass s 300 catalog:
- 8S3B25, DN25 1"
- 8S3B40, DN40 1 1/2"
- 8S3B08, DN08 3/8"
- 8S3B15, DN15 1/2"
- 8S3B50, DN50 2"
Promass s300 is a easy-to-clean, self-drainable single-tube system with a compact, easily accessible transmitter.
Measuring principle
Coriolis
Sensor features
Increased process safety easily cleanable and fully self-drainable tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Hygienic approvals and certificates
cGMP
Measuring principle
Coriolis
Product Headline
Easy...to...clean, self...drainable single...tube system with a compact, easily accessible transmitter.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Measuring principle
Coriolis
Product headline
Easy...to...clean, self...drainable single...tube system with a compact, easily accessible transmitter.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Sensor features
Increased process safety easily cleanable and fully self-drainable tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Transmitter features
Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety freely configurable I/O functionality. Integrated verification Heartbeat Technology.
Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range
DN 8 to 50 (в…њ to 2")
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)"
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error
Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressure
PN 40, Class 150, 20K
Medium temperature range
50 to +150 В°C (58 to +302 В°F)
Ambient temperature range
Standard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
AlSi10Mg, coated; stainless steel for hygenic transmitter design
Degree of protection
IP66/67, type 4X enclosure
IP69
Display/Operation
4-line backlit display with touch + control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs
Status input
4-20 mA input
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex
Product safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
Pressure approvals and certificates
PED, CRN
Material certificates
3.1 material
Hygienic approvals and certificates
3-A, EHEDG, cGMP
Measuring principle
Coriolis
Product headline
Easy...to...clean, self...drainable single...tube system with a compact, easily accessible transmitter.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Sensor features
Increased process safety easily cleanable and fully self-drainable tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Transmitter features
Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety freely configurable I/O functionality. Integrated verification Heartbeat Technology.
Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range
DN 8 to 50 (в…њ to 2")
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error
Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressure
PN 40, Class 150, 20K
Medium temperature range
50 to +150 В°C (58 to +302 В°F)
Ambient temperature range
Standard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
AlSi10Mg, coated; stainless steel for hygenic transmitter design
Degree of protection
IP66/67, type 4X enclosure
IP69
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs
Status input
4-20 mA input
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex
Product safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
Pressure approvals and certificates
PED, CRN
Material certificates
3.1 material
Hygienic approvals and certificates
3-A, EHEDG, cGMP
Buy Endress+Hauser Proline Promass S 300 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is an online electrical supply house. Our product catalog includes a lot of items of automation equipment: motor control components, industrial sensors, pneumatic automation, low voltage products, and others. We can provide you with the fastest delivery. By purchasing from our company, you receive quality products at the best prices. We always try to find the best delivery times and prices for all necessary products. We always fulfill our obligations.
Comments
No comments yet