Endress+Hauser Proline Prowirl D 200 / 7D2B
Vortex flowmeter

Endress+Hauser Proline Prowirl D 200 / 7D2B
Item Number: Proline Prowirl D 200 / 7D2B
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Measuring principle

Vortex

Product headline

Cost-effective wafer design, available as compact or remote device version.
Integrated temperature measurement for mass/energy flow of saturated steam.
For all basic applications and for 1-to-1 replacement of orifice plates.

Sensor features

Easy alignment of the sensor included centering rings. High availability proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance lifetime calibration.
Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.

Transmitter features

Convenient device wiring separate connection compartment. Safe operation no need to open the device due to display with touch control, background lighting. Integrated verification Heartbeat Technology.
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

Nominal diameter range

DN 15 to 150 (ВЅ to 6")

Wetted materials

Measuring tube: 1.4408 (C3FM)
DSC sensor: 1.4435 (316/316L)

Measured variables

Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam, gas): В±1.00 %
Mass flow (liquid): В±0.85%
Mass flow (steam, gas): В±1.7 %

Measuring range

Liquid: 0.16 to 625 mВі/h (0.09 to 368 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 2 to 8342 mВі/h (1.18 to 4910 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Standard: 40 to +260 В°C (40 to +500 В°F)
High/low temperature (option): 200 to +400 В°C (328 to +752 В°F)
High/low temperature (on request): 200 to +450 В°C (328 to +842 В°F)

Ambient temperature range

Compact version (standard): 40 to +80 В°C (40 to +176 В°F)
Compact version (option): 50 to +80 В°C (58 to +176 В°F)
Remote version (standard): 40 to +85 В°C (40 to +185 В°F)
Remote version (option): 50 to +85 В°C (58 to +185 В°F)

Sensor housing material

Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter housing material

AlSi10Mg, coated; 1.4404 (316L)

Degree of protection

Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation

4...line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

Outputs

4...20 mA HART (passive)
4...20 mA (passive)
Pulse/frequency/switch output (passive)

Inputs

Current input 4...20 mA (passive)

Digital communication

HART, PROFIBUS PA, FOUNDATION Fieldbus

Power supply

DC 12 to 35 V (4...20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4...20 mA HART, 4...20 mA)
DC 12 to 35 V (4...20 mA HART, pulse/frequency/switch output, 4...20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous area approvals

ATEX, IECEx, cCSAus, EAC

Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)

Pressure approvals and certificates

PED, CRN

Material certificates

3.1 material
NACE MR0175/MR0103, PMI (on request)

Measuring principle

Vortex

Product headline

Cost-effective wafer design, available as compact or remote device version.
Integrated temperature measurement for mass/energy flow of saturated steam.
For all basic applications and for 1-to-1 replacement of orifice plates.

Sensor features

Easy alignment of the sensor included centering rings. High availability proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance lifetime calibration.
Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.

Transmitter features

Convenient device wiring separate connection compartment. Safe operation no need to open the device due to display with touch control, background lighting. Integrated verification Heartbeat Technology.
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

Nominal diameter range

DN 15 to 150 (ВЅ to 6")

Wetted materials

Measuring tube: 1.4408 (C3FM)
DSC sensor: 1.4435 (316/316L)

Measured variables

Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam, gas): В±1.00 %
Mass flow (liquid): В±0.85%
Mass flow (steam, gas): В±1.7 %

Measuring range

Liquid: 0.16 to 625 mВі/h (0.09 to 368 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 2 to 8342 mВі/h (1.18 to 4910 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Standard: 40 to +260 В°C (40 to +500 В°F)
High/low temperature (option): 200 to +400 В°C (328 to +752 В°F)
High/low temperature (on request): 200 to +450 В°C (328 to +842 В°F)

Ambient temperature range

Compact version (standard): 40 to +80 В°C (40 to +176 В°F)
Compact version (option): 50 to +80 В°C (58 to +176 В°F)
Remote version (standard): 40 to +85 В°C (40 to +185 В°F)
Remote version (option): 50 to +85 В°C (58 to +185 В°F)

Sensor housing material

Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter housing material

AlSi10Mg, coated; 1.4404 (316L)

Degree of protection

Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation

4...line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

Outputs

4...20 mA HART (passive)
4...20 mA (passive)
Pulse/frequency/switch output (passive)

Inputs

4...20 mA (passive)

Digital communication

HART, PROFIBUS PA, FOUNDATION Fieldbus

Power supply

DC 12 to 35 V (4...20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4...20 mA HART, 4...20 mA)
DC 12 to 35 V (4...20 mA HART, pulse/frequency/switch output, 4...20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous area approvals

ATEX, IECEx, cCSAus

Other approvals and certificates

Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Pressure approvals and certificates

PED, CRN

Material certificates

3.1 material
NACE MR0175/MR0103, PMI (on request)

Measuring principle

Vortex

Product headline

Cost-effective wafer design, available as compact or remote device version.
Integrated temperature measurement for mass/energy flow of saturated steam.
For all basic applications and for 1-to-1 replacement of orifice plates.

Sensor features

Easy alignment of the sensor included centering rings. High availability proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance lifetime calibration.
Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.

Transmitter features

Convenient device wiring separate connection compartment. Safe operation no need to open the device due to display with touch control, background lighting. Integrated verification Heartbeat Technology.
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

Nominal diameter range

DN 15 to 150 (ВЅ to 6")

Wetted materials

Measuring tube: 1.4408 (C3FM)
DSC sensor: 1.4435 (316/316L)

Measured variables

Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam,, gas): В±1.00 %
Mass flow (liquid): В±0.85%
Mass flow (steam,, gas): В±1.7 %

Measuring range

Liquid: 0.16 to 625 mВі/h (0.09 to 368 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 2 to 8342 mВі/h (1.18 to 4910 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Standard: 40 to +260 В°C (40 to +500 В°F)
High/low temperature (option): 200 to +400 В°C (328 to +752 В°F)
High/low temperature (on request): 200 to +450 В°C (328 to +842 В°F)

Ambient temperature range

Compact version (standard): 40 to +80 В°C (40 to +176 В°F)
Compact version (option): 50 to +80 В°C (58 to +176 В°F)
Remote version (standard): 40 to +85 В°C (40 to +185 В°F)
Remote version (option): 50 to +85 В°C (58 to +185 В°F)

Sensor housing material

Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter housing material

AlSi10Mg, coated; 1.4404 (316L)

Degree of protection

Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation

4...line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

Outputs

4...20 mA HART (passive)
4...20 mA (passive)
Pulse/frequency/switch output (passive)

Inputs

4...20 mA (passive)

Digital communication

HART, PROFIBUS PA, FOUNDATION Fieldbus

Power supply

DC 12 to 35 V (4...20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4...20 mA HART, 4...20 mA)
DC 12 to 35 V (4...20 mA HART, pulse/frequency/switch output, 4...20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous area approvals

ATEX, IECEx, cCSAus, EAC

Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025)

Pressure approvals and certificates

PED, CRN

Material certificates

NACE MR0175/MR0103, PMI (on request)
3.1 material

Comments

No comments yet

Write a comment