Endress+Hauser Proline Prowirl R 200
Vortex flowmeter

Endress+Hauser Proline Prowirl R 200
We ship to United States of America!
Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam, gas): В±1.00 %
Mass flow (saturated steam): В±1.7% (temperature compensated); В±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): В±1.5 (temperature/pressure compensated); В±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): В±0.85%

Measuring range

Liquid: 0.1 to 540 mВі/h (0.061 to 320 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 0.52 to 7300 mВі/h (0.31 to 4300 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Medium temperature range

Standard: 40 to +260 В°C (40 to +500 В°F)
High/low temperature (option): 200 to +400 В°C (328 to +752 В°F)
High/low temperature (on request): 200 to +450 В°C (328 to +842 В°F)

Max. process pressure

PN 40, Class 300, 20K

Wetted materials

Measuring tube: 1.4408 (CF3M)
DSC sensor: 1.4404/F316/F316L
Process connection: 1.4404/F316/F316L

Item Number: Proline Prowirl R 200
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +

Flowmeter with best-in-class accuracy despite pipe reduction.

Measuring principle

Vortex

Product headline

Flowmeter with best-in-class accuracy despite pipe reduction.
Easy energy management integrated temperature and pressure measurement for steam and gases.
Dedicated to applications with very low flow or reduced flow.

Sensor features

Cost and time savings no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 most linear Vortex meter body. Long-term stability robust drift-free capacitive sensor. Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10").

Transmitter features

Cost and time savings no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 most linear Vortex meter body. Long-term stability robust drift-free capacitive sensor.
Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10"). Flexible positioning of pressure cell.

Nominal diameter range

DN 25 to 250 (1 to 10")

Wetted materials

Measuring tube: 1.4408 (CF3M)
DSC sensor: 1.4404/F316/F316L
Process connection: 1.4404/F316/F316L

Measured variables

Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam, gas): В±1.00 %
Mass flow (saturated steam): В±1.7% (temperature compensated); В±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): В±1.5 (temperature/pressure compensated); В±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): В±0.85%

Measuring range

Liquid: 0.1 to 540 mВі/h (0.061 to 320 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 0.52 to 7300 mВі/h (0.31 to 4300 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Standard: 40 to +260 В°C (40 to +500 В°F)
High/low temperature (option): 200 to +400 В°C (328 to +752 В°F)
High/low temperature (on request): 200 to +450 В°C (328 to +842 В°F)

Ambient temperature range

Compact version (standard): 40 to +80 В°C (40 to +176 В°F)
Compact version (option): 50 to +80 В°C (58 to +176 В°F)
Remote version (standard): 40 to +85 В°C (40 to +185 В°F)
Remote version (option): 50 to +85 В°C (58 to +185 В°F)

Sensor housing material

Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter housing material

AlSi10Mg, coated; 1.4404 (316L)

Degree of protection

Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation

4...line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

Outputs

4...20 mA HART (passive)
4...20 mA (passive)
Pulse/frequency/switch output (passive)

Inputs

4...20 mA (passive)

Digital communication

HART, PROFIBUS PA, FOUNDATION Fieldbus

Power supply

DC 12 to 35 V (4...20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4...20 mA HART, 4...20 mA)
DC 12 to 35 V (4...20 mA HART, pulse/frequency/switch output, 4...20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous area approvals

ATEX, IECEx, cCSAus, JPN, EAC, UK Ex

Product safety

CE, C-tick, EAC

Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)

Marine approvals and certificates

ABS, LR, BV, DNV GL

Pressure approvals and certificates

PED, CRN, AD 2000

Material certificates

3.1 material
NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614...1, similar to ASME IX (on request)

Measuring principle

Vortex

Product headline

Flowmeter with best-in-class accuracy despite pipe reduction.
Easy energy management integrated temperature and pressure measurement for steam and gases.
Dedicated to applications with very low flow or reduced flow.

Sensor features

Cost and time savings no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 most linear Vortex meter body. Long-term stability robust drift-free capacitive sensor. Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10").

Transmitter features

Cost and time savings no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 most linear Vortex meter body. Long-term stability robust drift-free capacitive sensor.
Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10"). Flexible positioning of pressure cell.

Nominal diameter range

DN 25 to 250 (1 to 10")

Wetted materials

Measuring tube: 1.4408 (CF3M)
DSC sensor: 1.4404/F316/F316L
Process connection: 1.4404/F316/F316L

Measured variables

Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam, gas): В±1.00 %
Mass flow (saturated steam): В±1.7% (temperature compensated); В±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): В±1.5 (temperature/pressure compensated); В±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): В±0.85%

Measuring range

Liquid: 0.1 to 540 mВі/h (0.061 to 320 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 0.52 to 7300 mВі/h (0.31 to 4300 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Standard: 40 to +260 В°C (40 to +500 В°F)
High/low temperature (option): 200 to +400 В°C (328 to +752 В°F)
High/low temperature (on request): 200 to +450 В°C (328 to +842 В°F)

Ambient temperature range

Compact version (standard): 40 to +80 В°C (40 to +176 В°F)
Compact version (option): 50 to +80 В°C (58 to +176 В°F)
Remote version (standard): 40 to +85 В°C (40 to +185 В°F)
Remote version (option): 50 to +85 В°C (58 to +185 В°F)

Sensor housing material

Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter housing material

AlSi10Mg, coated; 1.4404 (316L)

Degree of protection

Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation

4...line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

Outputs

4...20 mA HART (passive)
4...20 mA (passive)
Pulse/frequency/switch output (passive)

Inputs

4...20 mA (passive)

Digital communication

HART, PROFIBUS PA, FOUNDATION Fieldbus

Power supply

DC 12 to 35 V (4...20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4...20 mA HART, 4...20 mA)
DC 12 to 35 V (4...20 mA HART, pulse/frequency/switch output, 4...20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous area approvals

ATEX, IECEx, cCSAus, JPN, EAC, UK Ex

Product safety

CE, C-tick, EAC

Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)

Marine approvals and certificates

ABS, LR, BV, DNV GL

Pressure approvals and certificates

PED, CRN, AD 2000

Material certificates

3.1 material
NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614...1, similar to ASME IX (on request)

Measuring principle

Vortex

Product headline

Flowmeter with best-in-class accuracy despite pipe reduction.
Easy energy management integrated temperature and pressure measurement for steam and gases.
Dedicated to applications with very low flow or reduced flow.

Sensor features

Cost and time savings no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 most linear Vortex meter body. Long-term stability robust drift-free capacitive sensor. Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10").

Transmitter features

Cost and time savings no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 most linear Vortex meter body. Long-term stability robust drift-free capacitive sensor.
Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10"). Flexible positioning of pressure cell.

Nominal diameter range

DN 25 to 250 (1 to 10")

Wetted materials

Measuring tube: 1.4408 (CF3M)
DSC sensor: 1.4404/F316/F316L
Process connection: 1.4404/F316/F316L

Measured variables

Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam, gas): В±1.00 %
Mass flow (saturated steam): В±1.7% (temperature compensated); В±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): В±1.5 (temperature/pressure compensated); В±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): В±0.85%

Measuring range

Liquid: 0.1 to 540 mВі/h (0.061 to 320 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 0.52 to 7300 mВі/h (0.31 to 4300 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Standard: 40 to +260 В°C (40 to +500 В°F)
High/low temperature (option): 200 to +400 В°C (328 to +752 В°F)
High/low temperature (on request): 200 to +450 В°C (328 to +842 В°F)

Ambient temperature range

Compact version (standard): 40 to +80 В°C (40 to +176 В°F)
Compact version (option): 50 to +80 В°C (58 to +176 В°F)
Remote version (standard): 40 to +85 В°C (40 to +185 В°F)
Remote version (option): 50 to +85 В°C (58 to +185 В°F)

Sensor housing material

Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter housing material

AlSi10Mg, coated; 1.4404 (316L)

Degree of protection

Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation

4...line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

Outputs

4...20 mA HART (passive)
4...20 mA (passive)
Pulse/frequency/switch output (passive)

Inputs

4...20 mA (passive)

Digital communication

HART, PROFIBUS PA, FOUNDATION Fieldbus

Power supply

DC 12 to 35 V (4...20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4...20 mA HART, 4...20 mA)
DC 12 to 35 V (4...20 mA HART, pulse/frequency/switch output, 4...20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous area approvals

ATEX, IECEx, cCSAus, JPN, EAC, UK Ex

Product safety

CE, C-tick, EAC

Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)

Marine approvals and certificates

ABS, LR, BV, DNV GL

Pressure approvals and certificates

PED, CRN, AD 2000

Material certificates

3.1 material
NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614...1, similar to ASME IX (on request)