Endress+Hauser Proline t-mass T 150
Thermal mass flowmeter
- Overview +
- Comments +
t-mass T 150 catalog:
- 6TABL5, 110mm 4"
- 6TABLH, Hygienic Version
- 6TABL6, 330mm 13"
The flowmeter for reliable and easy monitoring of liquids.
Measuring principle
Thermal
Product headline
The flowmeter for reliable and easy monitoring of liquids. Dedicated to the
monitoring of conductive and non...conductive liquids.
Sensor features
High process safety high repeatability and linearity due to integrated temperature compensation. Cost...effective measurement easy installation, negligible pressure loss and maintenance...free. Reliable flow trending multivariable measurement. Insertion version for nominal diameter DN 40 to 1000 (1ВЅ to 40"). Sensor in standard or hygienic version.
Transmitter features
Fast and efficient commissioning guided operating menus. High plant availability self...diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4...20 mA HART, pulse/frequency/switch output.
Nominal diameter range
DN 40 to 1000 (1ВЅ to 40")
Wetted materials
Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection:
... Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
... Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
... Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
... Tri...Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864...1A, DN50 DIN 11864...1A: 1.4404 (316L)
Measured variables
Mass flow, temperature, volume flow
Max. measurement error
Flow: В±5 % o.f.s.
Measuring range
226 to 14 100 000 l/h (60 to 3 730 000 gal/h)
(under reference conditions)
Max. process pressure
PN 40
Medium temperature range
20 to +100 В°C (4 to +212 В°F)
Ambient temperature range
40 to +60 В°C (40 to +140 В°F)
Transmitter housing material
AlSi10Mg, coated
Degree of protection
IP66/67, type 4X enclosure
Display/Operation
4...line display with push buttons
Configuration via local display and operating tools possible
Outputs
4...20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs
Status input
Digital communication
HART
Power supply
DC 18 to 30 V
Hazardous area approvals
ATEX, IECEx, cCSAus
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Hygienic approvals: EHEDG, 3-A
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificates
CRN
Material certificates
3.1 material
Hygienic approvals and certificates
Sanitary approval: 3-A, EHEDG
Buy Endress+Hauser Proline t-mass T 150 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com offers an extensive range of industrial electrical products. We specialize in sourcing and delivering hard-to-find parts promptly. Our commitment to quality and competitive pricing makes us a preferred supplier. Partner with us for reliable and efficient electrical supply solutions.
Comments