Endress+Hauser Proline Promag 55S
Electromagnetic flowmeter

Endress+Hauser Proline Promag 55S

Electromagnetic flowmeter

Max. measurement error

Volume flow: В±0.5 % o.r.В± 1 mm/s (0.04 in/s)
Option: В±0.2 % o.r. В± 2 mm/s (0.08 in/s)

Item Number: Proline Promag 55S
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Electromagnetic flowmeter Promag S. Highly wear resistant flow meter with built-in solids content diagnostics. Stable measuring signal due to unique signal processing technology. Ideal for the toughest applications with high solids content and high product abrasion.

The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics.

Measuring range

0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)

Medium temperature range

0 to +60 В°C (+32 to +140 В°F), 0 to +80 В°C (+32 to +176 В°F), 20 to +50 В°C (4 to +122 В°F), 20 to +180 В°C (4 to +356 В°F), 20 to +150 В°C (4 to +266 В°F)

Max. process pressure

PN 40, Cl. 300, JIS 20 K

Wetted materials

Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber
Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum

Measuring principle

Electromagnetic

Product headline

The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics.
Superb signal stability due to unique signal processing.
Ideal for the most demanding applications with high solids content and high abrasion.

Sensor features

Maximum safety industry-optimized measuring electrodes and linings. Energy...saving flow measurement no pressure loss due to cross section constriction. Maintenance...free no moving parts.
Intensified coil system. Large range of liners. Solids content up to 80 % by weight.

Transmitter features

Highest performance with integrated solids measurement for demanding fluids. Highest safety integrated electrode cleaning. Automatic recovery of data for servicing.
4-line backlit display with touch control. Two switch outputs. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus.

Nominal diameter range

DN 15...600
1/2"...24"

Wetted materials

Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber
Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum

Measured variables

Volume flow, electrical conductivity, mass flow

Max. measurement error

Volume flow: В±0.5 % o.r.В± 1 mm/s (0.04 in/s)
Option: В±0.2 % o.r. В± 2 mm/s (0.08 in/s)

Measuring range

0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)

Max. process pressure

PN 40, Cl. 300, JIS 20 K

Medium temperature range

0 to +60 В°C (+32 to +140 В°F), 0 to +80 В°C (+32 to +176 В°F), 20 to +50 В°C (4 to +122 В°F), 20 to +180 В°C (4 to +356 В°F), 20 to +150 В°C (4 to +266 В°F)

Ambient temperature range

40 to +60 В°C (40 to +140 В°F)

Sensor housing material

Aluminum coated AlSi10Mg, carbon steel with protective varnish

Transmitter housing material

Powder-coated die-cast aluminum

Degree of protection

Standard: IP 67 (Type 4X enclosure) for transmitter and sensor
Optional: IP 68 (Type 6P enclosure) for remote version of Promag S sensor

Display/Operation

Liquid-crystal display: illuminated, four lines with 16 characters per line
Onsite operation with three optical sensor keys

Outputs

4...20mA
(active/passive) Pulse-/ Frequency output (active/passive)
Two status outputs

Inputs

Status
Current input

Digital communication

HART, PROFIBUS DP/PA, FOUNDATION Fieldbus

Power supply

AC 20 to 260 V
DC 20 to 64 V

Hazardous area approvals

ATEX, FM, CSA, UK Ex

Product safety

CE, C-tick, EAC marking

Pressure approvals and certificates

CRN, PED

Material certificates

3.1 material

Hygienic approvals and certificates

Drinking water approval:ACS, KTW/W270, NSF 61, WRAS BS 6920

Comments

No comments yet

Write a comment