Promass A Coriolis mass flowmeter. Simultaneous measurement of different process parameters (mass, density, temperature) for different process conditions during the measurement.
Measuring principleCoriolis
Product headlineThe single...tube flowmeter for smallest quantities with extended transmitter functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Sensor featuresHighest process safety self...drainable measuring tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in/outlet run needs. Nominal diameter: DN 1 to 4 (В№вЃ„в‚‚в‚„ to В№вЃ„в‚€"). Process pressure up to 400 bar (5800 psi).
Transmitter featuresQuality software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options numerous communication types. Automatic recovery of data for servicing. 4...line backlit display with touch control. Device in compact or remote version.
Nominal diameter rangeDN 1 to 4 (В№вЃ„в‚‚в‚„ to В№вЃ„в‚€")
Wetted materialsMeasuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement errorMass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cmВі
0 to 450 kg/h (0 to 16.5 lb/min)
Max. process pressurePN 40, Class 300, 20K, 400 bar (5800 psi)
Medium temperature range50 to +200 В°C (58 to +392 В°F)
Ambient temperature rangeStandard: 20 to +60 В°C (4 to +140 В°F)
Option: 40 to +60 В°C (40 to +140 В°F)
1.4301 (304), corrosion resistant
Transmitter housing materialPowder...coated die...cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation4...line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
4 modular outputs:
0...20 mA (active)/4...20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
2 modular inputs:
Status
0...20 mA (active)/4...20 mA (active/passive)
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485,
EtherNet/IP
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
CRN
3-A
CE, C-tick, EAC marking
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificatesCRN
Material certificates3.1 material
Hygienic approvals and certificates3-A
Measuring principleCoriolis
Characteristic / ApplicationThe single-tube system for highest measuring accuracy with minimal flow rates.
Ambient temperature-20...+65В°C
(-4...+140В°F)
-50...+200В°C
(-58...+392В°F)
PN 16...400
Cl 150...600
JIS 10...63K
904L/1.4539
Alloy C22/2.4602
4...20mA
Pulse/Frequency (10KHz), active/passive
Relays/Status
ATEX
FM
CSA
Coriolis
Product headlineThe single...tube flowmeter for smallest quantities with extended transmitter functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Sensor featuresHighest process safety self...drainable measuring tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in/outlet run needs. Nominal diameter: DN 1 to 4 (В№вЃ„в‚‚в‚„ to В№вЃ„в‚€"). Process pressure up to 400 bar (5800 psi).
Transmitter featuresQuality software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options numerous communication types. Automatic recovery of data for servicing. 4...line backlit display with touch control. Device in compact or remote version.
Nominal diameter rangeDN 1 to 4 (В№вЃ„в‚‚в‚„ to В№вЃ„в‚€")
Wetted materialsMeasuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement errorMass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cmВі
0 to 450 kg/h (0 to 16.5 lb/min)
Max. process pressurePN 40, Class 300, 20K, 400 bar (5800 psi)
Medium temperature range50 to +200 В°C (58 to +392 В°F)
Ambient temperature rangeStandard: 20 to +60 В°C (4 to +140 В°F)
Option: 40 to +60 В°C (40 to +140 В°F)
1.4301 (304), corrosion resistant
Transmitter housing materialPowder...coated die...cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation4...line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
4 modular outputs:
0...20 mA (active)/4...20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
2 modular inputs:
Status
0...20 mA (active)/4...20 mA (active/passive)
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
Power supplyDC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
ATEX, IECEx, FM, CSA, NEPSI
Product safetyCE, C-tick, EAC marking
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificatesCRN
Material certificates3.1 material
Hygienic approvals and certificates3-A
Measuring principleCoriolis
Product headlineThe single...tube flowmeter for smallest quantities with extended transmitter functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Sensor featuresHighest process safety self...drainable measuring tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in/outlet run needs. Nominal diameter: DN 1 to 4 (В№вЃ„в‚‚в‚„ to В№вЃ„в‚€"). Process pressure up to 400 bar (5800 psi).
Transmitter featuresQuality software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options numerous communication types. Automatic recovery of data for servicing. 4...line backlit display with touch control. Device in compact or remote version.
Nominal diameter rangeDN 1 to 4 (В№вЃ„в‚‚в‚„ to В№вЃ„в‚€")
Wetted materialsMeasuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement errorMass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cmВі
0 to 450 kg/h (0 to 16.5 lb/min)
Max. process pressurePN 40, Class 300, 20K, 400 bar (5800 psi)
Medium temperature range50 to +200 В°C (58 to +392 В°F)
Ambient temperature rangeStandard: 20 to +60 В°C (4 to +140 В°F)
Option: 40 to +60 В°C (40 to +140 В°F)
1.4301 (304), corrosion resistant
Transmitter housing materialPowder...coated die...cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation4...line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
4 modular outputs:
0...20 mA (active)/4...20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
2 modular inputs:
Status
0...20 mA (active)/4...20 mA (active/passive)
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485,
EtherNet/IP
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
CRN
3-A
CE, C-tick, EAC marking
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificatesCRN
Material certificates3.1 material
Hygienic approvals and certificates3-A
Buy Endress+Hauser Promass 83A with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. provides complete industrial automation solutions. With a wide selection of products and efficient delivery options, we meet your needs effectively. Our focus on quality and customer satisfaction distinguishes us. Experience our exceptional service and support for your automation needs.
Comments
No comments yet