Endress+Hauser Promass 84X
Coriolis flowmeter
- Overview +
- Comments +
Coriolis
Product headlineThe highest capacity four...tube flowmeter with custody transfer functionality. For highest flow rates and outstanding performance in on/offshore applications in the oil & gas industry.
Sensor featuresIncreased profit single installation point providing premium accuracy for large quantities. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in/outlet run needs. Nominal diameter: DN 300 to 400 (12 to 16"). Four...tube system with low pressure drop.
Transmitter featuresQuality designed for custody transfer; featuring worldwide recognized metrological approvals. Flexible data transfer options numerous communication types. Automatic recovery of data for servicing. 4...line backlit display with touch control. Device in compact or remote version.
Nominal diameter rangeDN 300 to 400 (12 to 16")
Wetted materialsMeasuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement errorMass flow (liquid): В±0.1 (standard), 0.05 % (option)
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.35 %
Density (liquid): В±0.0005 g/cmВі
0 to 4100 t/h (0 to 4520 tn. sh./h)
Max. process pressurePN 100, Class 600
Medium temperature range50 to +180 В°C (58 to +356 В°F)
Ambient temperature rangeStandard: 20 to +60 В°C (4 to +140 В°F)
Option: 40 to +60 В°C (40 to +140 В°F)
1.4404 (316L), highest corrosion resistance
Transmitter housing materialPowder...coated die...cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation4...line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
4 modular outputs:
0...20 mA (active)/4...20 mA (active/passive)
Pulse/frequency/switch output (passive)
phase...shifted pulse
Relay
1 modular input: status
Digital communicationHART
Modbus RS485
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
ATEX, IECEx, FM, CSA
Other approvals and certificates3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, custody transfer, PED, CRN, AD 2000, NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME, NORSOK
Product safetyCE, C-tick, EAC marking
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Custody transfer approvals: MI-005 (liquid)
PED, CRN, AD 2000
Material certificates3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Coriolis
Product headlineThe highest capacity four...tube flowmeter with custody transfer functionality. For highest flow rates and outstanding performance in on/offshore applications in the oil & gas industry.
Sensor featuresIncreased profit single installation point providing premium accuracy for large quantities. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in/outlet run needs. Nominal diameter: DN 300 to 400 (12 to 16"). Four...tube system with low pressure drop.
Transmitter featuresQuality designed for custody transfer; featuring worldwide recognized metrological approvals. Flexible data transfer options numerous communication types. Automatic recovery of data for servicing. 4...line backlit display with touch control. Device in compact or remote version.
Nominal diameter rangeDN 300 to 400 (12 to 16")
Wetted materialsMeasuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement errorMass flow (liquid): В±0.1 (standard), 0.05 % (option)
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.35 %
Density (liquid): В±0.0005 g/cmВі
0 to 4100 t/h (0 to 4520 tn. sh./h)
Max. process pressurePN 100, Class 600
Medium temperature range50 to +180 В°C (58 to +356 В°F)
Ambient temperature rangeStandard: 20 to +60 В°C (4 to +140 В°F)
Option: 40 to +60 В°C (40 to +140 В°F)
1.4404 (316L), highest corrosion resistance
Transmitter housing materialPowder...coated die...cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation4...line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
4 modular outputs:
0...20 mA (active)/4...20 mA (active/passive)
Pulse/frequency/switch output (passive)
phase...shifted pulse
Relay
1 modular input: status
Digital communicationHART
Modbus RS485
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
ATEX, IECEx, FM, CSA, EAC
Other approvals and certificates3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, custody transfer, PED, CRN, AD 2000, NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME, NORSOK
Product safetyCE, C-tick, EAC marking
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Custody transfer approvals: MI-005 (liquid)
PED, CRN, AD 2000
Material certificates3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Buy Endress+Hauser Promass 84X with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. provides complete industrial automation solutions. With a wide selection of products and efficient delivery options, we meet your needs effectively. Our focus on quality and customer satisfaction distinguishes us. Experience our exceptional service and support for your automation needs.
Comments
No comments yet