Endress+Hauser Proline Prosonic Flow 93P
Ultrasonic flowmeter

Endress+Hauser Proline Prosonic Flow 93P

Ultrasonic flow meter

Max. measurement error

Volume flow:
В±3% o.r. for DN15
В±2% o.r. for DN25 to DN200
В±2% o.r. above DN200

Item Number: Proline Prosonic Flow 93P
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Prosonic ultrasonic clamp-on flowmeter. Designed to measure the volume flow of liquid products in the chemical industry. It has a modular design and a unified control scheme.

Flowmeter for hazardous area installations with a wide range of analog and digital outputs.

Measuring range

0.3 to 10 m/s (1 to 33 ft/s)

Medium temperature range

DN15 to 65
-40 to +100В°C (-40 +212 В°F)
-40 to +150В°C (-40 +302 В°F) option
DN50 to 4000
-40 to +80В°C (-40 +276 В°F)
-40 to +170В°C (-40 +338 В°F) option

Max. process pressure

N/A

Wetted materials

Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304

Measuring principle

Ultrasonic flow

Product headline

Flowmeter for hazardous area installations with a wide range of analog and digital outputs.
Automatic frequency scan for maximum measuring performance.
Ideal clamp-on device for applications with chemicals, solvents, liquid hydrocarbons, acids, alkalis.

Sensor features

Increased safety for chemical and petrochemical industry international hazardous area approvals. Long-term stable signal maintenance-free permanent mounting from outside with coupling pads. Process transparency diagnostic capability.
Medium temperature: 40 to 170 В°C (40 to 338 В°F). Wide nominal diameter range: DN 15 to 4000 (ВЅ to 160"). Process piping unaffected by meter installation.

Transmitter features

Highest performance extended functionality and diagnostics. Flexible data transfer options numerous communication types. Automatic recovery of data for servicing.
Aluminium transmitter housing. 4...line backlit display with touch control. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus.

Nominal diameter range

Single channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160")
Dual channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160")

Wetted materials

Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304

Measured variables

Volume flow channel 1&2, average volume flow, volume flow difference, sound velocity, flow velocity, totalizer

Max. measurement error

Volume flow:
В±3% o.r. for DN15
В±2% o.r. for DN25 to DN200
В±2% o.r. above DN200

Measuring range

0.3 to 10 m/s (1 to 33 ft/s)

Max. process pressure

N/A

Medium temperature range

DN15 to 65
-40 to +100В°C (-40 +212 В°F)
-40 to +150В°C (-40 +302 В°F) option
DN50 to 4000
-40 to +80В°C (-40 +276 В°F)
-40 to +170В°C (-40 +338 В°F) option

Ambient temperature range

-20 to +60 В°C (-4 to +140 В°F)
-40 to +60 В°C (-40 to +140 В°F) optional

Sensor housing material

N/A

Transmitter housing material

Wall-mounted housing: powder-coated die-cast aluminum

Degree of protection

IP67, type 4X for transmitter
IP68 type 6P for sensors. Transmitter: IP67, type 4X enclosure

Display/Operation

4 lines backlit display with three optical keys

Outputs

1x 4-20 mA HART
1x Pulse/frequency/switch output (passive)

Inputs

N/A

Digital communication

HART
PROFIBUS PA
Profibus DP
FOUNDATION Fieldbus

Power supply

85 to 260 V AC
20 to 55 V AC
16 to 62V DC

Hazardous area approvals

ATEX, FM/CSA, NEPSI, JPN

Other approvals and certificates

Flowmeter verification for DN15, 25, 40, 50 & 100 only
Marine certificate
EAC marking

Product safety

EAC marking

Metrological approvals and certificates

Flowmeter verification for DN15, 25, 40, 50 & 100 only

Marine approvals and certificates

Marine certificate