Endress+Hauser Proline Prosonic Flow 93W
Ultrasonic flowmeter

Endress+Hauser Proline Prosonic Flow 93W

Ultrasonic flow meter

Max. measurement error

Volume flow:
В±3% o.r. for DN15
В±2% o.r. for DN25 to 200
В±2% o.r. above DN200

Measuring range

0.3 to 10 m/s (1 to 33 ft/s)

Medium temperature range

Clamp-on: 20 to +80 В°C (4 to +176 В°F)
Insertion version: 40 to +80 В°C

Max. process pressure

N/A

Wetted materials

Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304

Item Number: Proline Prosonic Flow 93W
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Prosonic ultrasonic clamp-on flowmeter. Suitable for measuring the flow of technical and drinking water, wastewater.

Device with automatic frequency scan for max. measuring performance with a wide range of outputs.

Measuring principle

Ultrasonic flow

Product headline

Device with automatic frequency scan for max. measuring performance with a wide range of outputs.
Clamp-on flow measurement of process water, salt water, demineralized water, drinking & wastewater.

Sensor features

Low capital investment cost-effectiveness increases with pipe diameter (up to DN 4000/156"). Long-term stable signal maintenance-free permanent mounting from outside with coupling pads. Process transparency diagnostic capability.
Medium temperature: 20 to +80 В°C (-4 to +176 В°F). Degree of protection IP68 (Type 6P enclosure) for pipes under water. Shock and vibration resistance according to IEC 68-2-6.

Transmitter features

Highest performance extended functionality and diagnostics. Flexible data transfer options numerous communication types. Automatic recovery of data for servicing.
Aluminium transmitter housing. 4...line backlit display with touch control. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus.

Nominal diameter range

Single channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160")
Dual channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160")

Wetted materials

Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304

Measured variables

Volume flow channel 1&2, average volume flow, volume flow difference, sound velocity, flow velocity, totalizer

Max. measurement error

Volume flow:
В±3% o.r. for DN15
В±2% o.r. for DN25 to 200
В±2% o.r. above DN200

Measuring range

0.3 to 10 m/s (1 to 33 ft/s)

Max. process pressure

N/A

Medium temperature range

Clamp-on: 20 to +80 В°C (4 to +176 В°F)
Insertion version: 40 to +80 В°C

Ambient temperature range

-20 to +60 В°C (-4 to +140 В°F)

Sensor housing material

N/A

Transmitter housing material

Wall-mounted housing: powder-coated die-cast aluminum

Degree of protection

IP67, type 4X for transmitter, IP68 (option)
IP67 type 4X for sensors
IP68 type 6P for sensors (option). Transmitter: IP67, type 4X enclosure

Display/Operation

4 lines backlit display with three optical keys

Outputs

1x 4-20 mA HART
1x Pulse/frequency/switch output (passive)

Inputs

N/A

Digital communication

HART, PROFIBUS PA, PROFIBUS DP, FOUNDATION Fieldbus

Power supply

AC 85 to 260 V
AC 20 to 55 V
DC 16 to 62 V

Hazardous area approvals

ATEX, FM, CSA

Other approvals and certificates

Flowmeter verification for DN15, 25, 40, 50, 100, 250, 400 only
Marine certificate
EAC marking

Product safety

CE, C-Tick, EAC marking

Metrological approvals and certificates

Flowmeter verification for DN15, 25, 40, 50, 100, 250, 400 only

Marine approvals and certificates

Marine certificate

Comments

No comments yet

Write a comment