Endress+Hauser Proline Prosonic Flow 93W
Ultrasonic flowmeter
Ultrasonic flow meter
Max. measurement errorVolume flow:
В±3% o.r. for DN15
В±2% o.r. for DN25 to 200
В±2% o.r. above DN200
0.3 to 10 m/s (1 to 33 ft/s)
Medium temperature rangeClamp-on: 20 to +80 В°C (4 to +176 В°F)
Insertion version: 40 to +80 В°C
N/A
Wetted materialsClamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304
- Overview +
- Comments +
Prosonic ultrasonic clamp-on flowmeter. Suitable for measuring the flow of technical and drinking water, wastewater.
Device with automatic frequency scan for max. measuring performance with a wide range of outputs.
Measuring principleUltrasonic flow
Product headlineDevice with automatic frequency scan for max. measuring performance with a wide range of outputs.
Clamp-on flow measurement of process water, salt water, demineralized water, drinking & wastewater.
Low capital investment cost-effectiveness increases with pipe diameter (up to DN 4000/156"). Long-term stable signal maintenance-free permanent mounting from outside with coupling pads. Process transparency diagnostic capability.
Medium temperature: 20 to +80 В°C (-4 to +176 В°F). Degree of protection IP68 (Type 6P enclosure) for pipes under water. Shock and vibration resistance according to IEC 68-2-6.
Highest performance extended functionality and diagnostics. Flexible data transfer options numerous communication types. Automatic recovery of data for servicing.
Aluminium transmitter housing. 4...line backlit display with touch control. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus.
Single channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160")
Dual channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160")
Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304
Volume flow channel 1&2, average volume flow, volume flow difference, sound velocity, flow velocity, totalizer
Max. measurement errorVolume flow:
В±3% o.r. for DN15
В±2% o.r. for DN25 to 200
В±2% o.r. above DN200
0.3 to 10 m/s (1 to 33 ft/s)
Max. process pressureN/A
Medium temperature rangeClamp-on: 20 to +80 В°C (4 to +176 В°F)
Insertion version: 40 to +80 В°C
-20 to +60 В°C (-4 to +140 В°F)
Sensor housing materialN/A
Transmitter housing materialWall-mounted housing: powder-coated die-cast aluminum
Degree of protectionIP67, type 4X for transmitter, IP68 (option)
IP67 type 4X for sensors
IP68 type 6P for sensors (option). Transmitter: IP67, type 4X enclosure
4 lines backlit display with three optical keys
Outputs1x 4-20 mA HART
1x Pulse/frequency/switch output (passive)
N/A
Digital communicationHART, PROFIBUS PA, PROFIBUS DP, FOUNDATION Fieldbus
Power supplyAC 85 to 260 V
AC 20 to 55 V
DC 16 to 62 V
ATEX, FM, CSA
Other approvals and certificatesFlowmeter verification for DN15, 25, 40, 50, 100, 250, 400 only
Marine certificate
EAC marking
CE, C-Tick, EAC marking
Metrological approvals and certificatesFlowmeter verification for DN15, 25, 40, 50, 100, 250, 400 only
Marine approvals and certificatesMarine certificate
Buy Endress+Hauser Proline Prosonic Flow 93W with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is fast developing company in automation parts. We can help you save time and reject from many other suppliers due to the large variety of offering goods. Our sales are spread all over the world. Due to providing low prices you can save money. A personal manager will attend you at all stages of the deal. We respect your needs and are interested in their total satisfaction.