Endress+Hauser Prosonic FDU91
Ultrasonic measurement Time-of-Flight

Endress+Hauser Prosonic FDU91

Ultrasonic measurement Time-of-Flight

Process temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Max. measurement distance

5 m (16ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

PVDF (fully welded IP68 / NEMA 6P)

Item Number: Prosonic FDU91
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Ultrasonic level and flow sensor Prosonic S FDU91. Continuous measurement method. For connection to Prosonic S FMU90/FMU95 transmitter. It has a built-in temperature sensor to correct the signal's time of flight.

Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 10m).

Measuring principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

Supply / Communication

4-wire (HART , Profibus DP)

Accuracy

+/- 2mm + 0.17% of measured distance

Ambient temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Main wetted parts

PVDF (fully welded IP68 / NEMA 6P)

Process connection

G / NPT 1"

Blocking distance

0.3 m (1 ft)

Max. measurement distance

5 m (16ft)

Communication

Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC Ex

Options

Second 4...20mA output

Components

Transmitter:
FMU90

Measuring principle

Ultrasonic

Product headline

Version with separate transmitter in field housing or top hat rail housing
Cost effective solution for open channel flow measurement in water / wastewater plants

Max. measurement error

accuracy:
distance measurement: +/- 2mm + 0.17%
resolution:
distance measurement: 1mm

Measuring range

max measuring distance up to 10m / 32ft

Max. process pressure

atm.

Medium temperature range

-40...80В°C
(-40...176В°F)

Degree of protection

IP68

Display/Operation

Transmitter

Outputs

Transmitter:
4...20mA HART
Option: second 4...20mA output

Inputs

Transmitter

Digital communication

HART, PROFIBUS DP

Hazardous area approvals

ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

Measuring principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

Supply / Communication

4-wire (HART, Profibus DP)

Accuracy

+/- 2 mm + 0.17% of measured distance

Ambient temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Main wetted parts

PVDF (fully welded IP68 / NEMA6P)

Process connection

G / NPT 1"

Blocking distance

0.3 m (1 ft)

Application

Application

Max. measurement distance

Max. measurement distance

Communication

Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

Options

Second 4...20 mA output

Components

Transmitter:
FMU90, FMU95

Application limits

Application limits

Comments

No comments yet