Endress+Hauser Prosonic FDU91F
Ultrasonic measurement Time-of-Flight

Endress+Hauser Prosonic FDU91F

Ultrasonic Level Gauge

Process temperature

-40 В°C ... 105 В°C
(-40 В°F ... 221 В°F)
30 min: 135 В°C / 275 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Max. measurement distance

5 m (16 ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

316L (fully welded IP68 / NEMA 6P)

Item Number: Prosonic FDU91F
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Ultrasonic level and flow sensor Prosonic S FDU91F. Remote version with field housing or DIN rail mounting, distance between sensor and transmitter can be up to 300m

Hygienic sensor for level and flow measurement for connection to FMU9x (measuring range up to 10m).

Measuring principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

Supply / Communication

4-wire (HART, Profibus DP)

Accuracy

+/- 2mm + 0.17% of measured distance

Ambient temperature

-40 В°C ... 105 В°C
(-40 В°F ... 221 В°F)

Process temperature

-40 В°C ... 105 В°C
(-40 В°F ... 221 В°F)
30 min: 135 В°C / 275 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Main wetted parts

316L (fully welded IP68 / NEMA 6P)

Process connection

G / NPT 1", DN80 / 100, ASME 3" / 4"

Process connection hygienic

Tri-Clamp ISO2852, DN80 (3 1/2"), DN100 (4")

Blocking distance

0.3 m (1 ft)

Max. measurement distance

5 m (16 ft)

Communication

Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

Design approvals

EN 10204-3.1

Options

Second 4...20 mA output

Components

Transmitter:
FMU90

Measuring principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

Specialities

Specialities

Supply / Communication

4-wire (HART, Profibus DP)

Accuracy

+/- 2 mm + 0.17% of measured distance

Ambient temperature

-40 В°C ... 105 В°C
(-40 В°F ... 221 В°F)

Process temperature

-40 В°C ... 105 В°C
(-40 В°F ... 221 В°F)
CIP: 30 min: 135 В°C
(30 min: 275 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Main wetted parts

316L (fully welded IP68 / NEMA 6P)

Process connection

G / NPT 1", DN80 / 100, ASME 3" / 4"

Process connection hygienic

Tri-Clamp ISO2852, DN80 3 1/2", DN100 4"

Blocking distance

0.3 m (1 ft)

Application

Application

Max. measurement distance

Max. measurement distance

Communication

Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

Design approvals

EN 10204-3.1

Hygienic approvals

3A

Options

Options

Components

Transmitter:
FMU90, FMU95

Application limits

Application limits

Comments

No comments yet

Write a comment