Endress+Hauser Prosonic FDU92
Ultrasonic measurement Time-of-Flight

Endress+Hauser Prosonic FDU92

Ultrasonic Level Gauge

Process temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Max. measurement distance

10 m (33 ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

PVDF (fully welded IP68 / NEMA 6P)

Item Number: Prosonic FDU92
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Ultrasonic level and flow sensor Prosonic S FDU92. Continuous measurement method. For connection to Prosonic S FMU90 transmitter. It has a built-in temperature sensor to correct the signal's time of flight.

Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 20m).

Measuring principle

Ultrasonic

Product headline

Version with separate transmitter in field housing or top hat rail housing
Cost effective solution for open channel flow measurement in water / wastewater plants

Max. measurement error

accuracy:
distance measurement: +/- 2mm + 0.17%

Measuring range

max measuring distance up to 20m / 65ft

Max. process pressure

atm.

Medium temperature range

-40...95В°C
(-40...203В°F)

Degree of protection

IP68

Display/Operation

Transmitter

Outputs

Transmitter:
4...20mA HART
Option: second 4...20mA output

Inputs

Transmitter

Digital communication

HART, PROFIBUS DP

Hazardous area approvals

ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

Measuring principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

Supply / Communication

4-wire (HART , Profibus DP)

Accuracy

+/- 2mm + 0.17% of measured distance

Ambient temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Main wetted parts

PVDF (fully welded IP68 / NEMA 6P)

Process connection

G / NPT 1"

Blocking distance

0.4 m (1.3 ft)

Max. measurement distance

10 m (33 ft)

Communication

Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC Ex

Options

Second 4...20mA output

Components

Transmitter:
FMU90

Measuring principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

Supply / Communication

4-wire (HART, Profibus DP)

Accuracy

+/- 2mm + 0.17% of measured distance

Ambient temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Main wetted parts

PVDF (fully welded IP68 / NEMA 6P)

Process connection

G / NPT 1"

Blocking distance

0.4 m (1.3 ft)

Application

Application

Max. measurement distance

Max. measurement distance

Communication

Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

Options

Second 4...20 mA output

Components

Transmitter:
FMU90, FMU95

Application limits

Application limits

Comments

No comments yet

Write a comment