Endress+Hauser Prosonic FDU92
Ultrasonic measurement Time-of-Flight
Ultrasonic Level Gauge
Process temperature-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)
0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
10 m (33 ft)
Accuracy+/- 2mm + 0.17% of measured distance
Main wetted partsPVDF (fully welded IP68 / NEMA 6P)
- Overview
- Comments
Ultrasonic level and flow sensor Prosonic S FDU92. Continuous measurement method. For connection to Prosonic S FMU90 transmitter. It has a built-in temperature sensor to correct the signal's time of flight.
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 20m).
Measuring principleUltrasonic
Product headlineVersion with separate transmitter in field housing or top hat rail housing
Cost effective solution for open channel flow measurement in water / wastewater plants
accuracy:
distance measurement: +/- 2mm + 0.17%
max measuring distance up to 20m / 65ft
Max. process pressureatm.
Medium temperature range-40...95В°C
(-40...203В°F)
IP68
Display/OperationTransmitter
OutputsTransmitter:
4...20mA HART
Option: second 4...20mA output
Transmitter
Digital communicationHART, PROFIBUS DP
Hazardous area approvalsATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
Measuring principleUltrasonic
Characteristic / ApplicationSeparated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Supply / Communication4-wire (HART , Profibus DP)
Accuracy+/- 2mm + 0.17% of measured distance
Ambient temperature-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)
-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)
0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
PVDF (fully welded IP68 / NEMA 6P)
Process connectionG / NPT 1"
Blocking distance0.4 m (1.3 ft)
Max. measurement distance10 m (33 ft)
CommunicationTransmitter:
4 ... 20 mA HART
Profibus DP
ATEX, FM, CSA, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC Ex
OptionsSecond 4...20mA output
ComponentsTransmitter:
FMU90
Ultrasonic
Characteristic / ApplicationSeparated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
Supply / Communication4-wire (HART, Profibus DP)
Accuracy+/- 2mm + 0.17% of measured distance
Ambient temperature-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)
-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)
0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
PVDF (fully welded IP68 / NEMA 6P)
Process connectionG / NPT 1"
Blocking distance0.4 m (1.3 ft)
ApplicationApplication
Max. measurement distanceMax. measurement distance
CommunicationTransmitter:
4 ... 20 mA HART
Profibus DP
ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
OptionsSecond 4...20 mA output
ComponentsTransmitter:
FMU90, FMU95
Application limits