Endress+Hauser Prosonic FDU93
Ultrasonic measurement Time-of-Flight

Endress+Hauser Prosonic FDU93
We ship to United States of America!

Ultrasonic sensor for level and flow measurement

Process temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 3 bar abs
(10 psi ... 43 psi)

Max. measurement distance

Max. measurement distance

Accuracy

+/- 2 mm + 0.17% of measured distance

Main wetted parts

UP (unsaturated polyester)
Silicon / Al PTFE coated

Item Number: Prosonic FDU93
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +

Ultrasonic flow and level sensor Prosonic S FDU93. Continuous measurement method.

For connection to Prosonic S FMU90 transmitter. It has a built-in temperature sensor to correct the time of flight of the signal. Increased measurement accuracy even with temperature changes. Remote version with field housing or DIN rail mounting, distance between sensor and transmitter can be up to 300m

Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 25m).

Measuring principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

Supply / Communication

4-wire (HART, Profibus DP)

Accuracy

+/- 2 mm + 0.17% of measured distance

Ambient temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 3 bar abs
(10 psi ... 43 psi)

Main wetted parts

UP (unsaturated polyester)
Silicon / Al PTFE coated

Process connection

G / NPT 1"

Blocking distance

0.6 m (2 ft)

Application

Application

Max. measurement distance

Max. measurement distance

Communication

Transmitter:
4...20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

Options

Second 4...20 mA output

Components

Transmitter:
FMU90, FMU95

Measuring principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

Supply / Communication

4-wire (HART , Profibus DP)

Accuracy

+/- 2mm + 0.17% of measured distance

Ambient temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 3 bar abs
(10 psi ... 43 psi)

Main wetted parts

UP (unsaturated polyester)
Silicon / Al PTFE coated

Process connection

G / NPT 1"

Blocking distance

0.6 m (2 ft)

Max. measurement distance

15 m (50 ft)

Communication

Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

Options

Second 4...20mA output

Components

Transmitter:
FMU90


Buy Endress+Hauser Prosonic FDU93 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is fast developing company in automation parts. We can help you save time and reject from many other suppliers due to the large variety of offering goods. Our sales are spread all over the world. Due to providing low prices you can save money. A personal manager will attend you at all stages of the deal. We respect your needs and are interested in their total satisfaction.

Comments

No comments yet