Endress+Hauser Prosonic FDU95
Ultrasonic measurement Time-of-Flight

Endress+Hauser Prosonic FDU95

Ultrasonic Level Gauge

Process temperature

-40 В°C ... 80 В°C
or 150 В°C
(-40 В°F ... 176 В°F
or 302 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar...1.5 bar abs
(10 psi...22 psi)

Max. measurement distance

45 m (148 ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

UP (unsaturated polyester)
Silicon / PE foam (80В°C / 176В°F)
Silicon / stainless steal (150В°C / 302В°F))

Item Number: Prosonic FDU95
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Ultrasonic flow and level sensor Prosonic S FDU95. Continuous measurement method. For connection to Prosonic S FMU90 transmitter. It has a built-in temperature sensor to correct the time of flight of the signal. Increased measurement accuracy even with temperature changes.

Ultrasonic sensor for level measurement for connection to FMU9x (measuring range up to 45m).

Measuring principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

Supply / Communication

4-wire (HART , Profibus DP)

Accuracy

+/- 2mm + 0.17% of measured distance

Ambient temperature

-40 В°C ... 80 В°C
or 150 В°C
(-40 В°F ... 176 В°F
or 302 В°F)

Process temperature

-40 В°C ... 80 В°C
or 150 В°C
(-40 В°F ... 176 В°F
or 302 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar...1.5 bar abs
(10 psi...22 psi)

Main wetted parts

UP (unsaturated polyester)
Silicon / PE foam (80В°C / 176В°F)
Silicon / stainless steal (150В°C / 302В°F))

Process connection

G / NPT 1"

Blocking distance

0.7 m / 80 В°C
(2.3 ft / 176 В°F)
0.9 m / 150 В°C
(2.9 ft / 302 В°F)

Max. measurement distance

45 m (148 ft)

Communication

Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

Options

Second 4...20mA output

Components

Transmitter:
FMU90

Measuring principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

Supply / Communication

4-wire (HART, Profibus DP)

Accuracy

+/- 2 mm + 0.17% of measured distance

Ambient temperature

-40 В°C...80 В°C
or 150 В°C,
(-40 В°F...176 В°F
or 302 В°F)

Process temperature

-40 В°C...80 В°C
or 150 В°C,
(-40 В°F...176 В°F
or 302 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar...1.5 bar abs
(10 psi...22 psi)

Main wetted parts

UP (unsaturated polyester)
Silicon / Al PTFE coated

Process connection

G / NPT 1"

Blocking distance

0.7 m / 80 В°C,
(2.3 ft / 176 В°F),
0.9 m / 150 В°C,
(2.9 ft / 302 В°F)

Max. measurement distance

45 m (148 ft)

Communication

Transmitter:
4...20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

Options

Second 4...20 mA output

Components

Transmitter:
FMU90, FMU95

Comments

No comments yet