Endress+Hauser RA33
Batch Controller

Endress+Hauser RA33
Input

1 x analogue (I) / pulse (for flow)
1 x RTD (for temperature)
1 x analogue (I) (for density)
Loop power supply 24V DC (+/-16%)

Output

1 x analogue (I) / pulse (active)
2 x open collector

Display

160 x 80 Dot-Matrix LCD with white backlit
Colour change in case of alarm event
Active display area 70 x 34 mm

Calculations

Volume calculation

Item Number: RA33
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Recording and controlling of batch operations.

Measuring principle

Application manager

Measuring principle

Batch controller

Function

Filling & dosing

Calculations

Volume calculation

Number of applications

1

Data storage

yes

Calculation standards

ASTM D1250-04

Communication

RS232
USB
Ethernet
Modbus TCP
Modbus RTU

Power supply

Not defined

Loop power supply

Low voltage power supply:
100 bis 230 V AC (-15% / +10%)
Small voltage power supply:
24 V DC (-50% / +75%)
24 V AC (В±50%)

Protection class

IP65

Input

1 x analogue (I) / pulse (for flow)
1 x RTD (for temperature)
1 x analogue (I) (for density)
Loop power supply 24V DC (+/-16%)

Output

1 x analogue (I) / pulse (active)
2 x open collector

Dimensions (WxHxD)

144 x 144 x 103.1 mm (5.67" x 5.67" x 4.06")

Operation

3 operation buttons and 14 function buttons for batch operation or via FieldCare
Read out of historical / logged data via Field Data Manager software (SQL database and visualization interface)
Selectable language

Display

160 x 80 Dot-Matrix LCD with white backlit
Colour change in case of alarm event
Active display area 70 x 34 mm

Software functions

Volume calculation
1 or 2 stage operation
Manual and automatic overrun correction
Volume correction factor (VCF) according ASTM D1250-04 for generalized crude oils, refined products and lubricating oils

Certificates

CE
CSA GP
NTEP (USA)

Measuring principle

Batch controller

Function

Filling & dosing

Certification

CE
UL listed
CSA GP

Input

1 x analogue (I) / pulse (for flow)
1 x RTD (for temperature)
1 x analogue (I) (for density)
Loop power supply 24V DC (+/-16%)

Output

1 x analogue (I) / pulse (active)
2 x open collector

Relay output

2 x relay

Auxiliary power supply / Loop power supply

Low voltage power supply:
100 bis 230 V AC (-15% / +10%)
Small voltage power supply:
24 V DC (-50% / +75%), 24 V AC (В±50%)

Dimensions (wxhxd)

144 x 144 x 103.1 mm
(5.67" x 5.67" x 4.06")

Software

Volume calculation
1 or 2 stage operation
Manual and automatic overrun correction
Volume correction factor (VCF) according ASTM D1250-04 for generalized crude oils, refined products and lubricating oils

Operation

3 operation buttons and 14 function buttons for batch operation or via FieldCare
Read out of historical / logged data via Field Data Manager software (SQL database and visualization interface)
Selectable language

Display

160 x 80 Dot-Matrix LCD with white backlit
Colour change in case of alarm event
Active display area 70 x 34 mm

Comments

No comments yet

Write a comment