Endress+Hauser Micropilot FMR60
Radar measurement

Endress+Hauser Micropilot FMR60
Accuracy

+/- 1 mm (0.04 in)

Process temperature

-40...+130 В°C
(-40...+266 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ...16 bar
(Vacuum ... 232 psi)

Max. measurement distance

50 m (164 ft)

Main wetted parts

PTFE antenna
PP or 316L process connections

Item Number: Micropilot FMR60
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

The standard sensor for highest demands in liquid level measurement with 80GHz technology.

Measuring principle

Level radar

Characteristic / Application

For basic level measurement in liquids, pastes and slurries;
non affected by changing media, temperature changes, gas blankets or vapor;
For applications with many obstacles due to the very small beam angle.

Specialities

Heartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning,
Operation and maintenance SmartBlue App,
Safety and reliability with Multi-Echo Tracking
HistoROM
RFID TAG for easy identification

Supply / Communication

2-wire (HART)
BluetoothВ® wireless technology and App (optional)

Frequency

W-band (~80 GHz)

Accuracy

+/- 1 mm (0.04 in)

Ambient temperature

-40...+80 В°C
(-40...+176 В°F)

Process temperature

-40...+130 В°C
(-40...+266 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ...16 bar
(Vacuum ... 232 psi)

Main wetted parts

PTFE antenna
PP or 316L process connections

Process connection

Thread:
G1-1/2", MNPT1-1/2";
Flange:
UNI DN80...DN150 (3"...6")

Max. measurement distance

50 m (164 ft)

Communication

4...20 mA HART,
Additional switch,
BluetoothВ® wireless technology

Certificates / Approvals

ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex

Safety approvals

Overfill protection WHG
SIL 2, SIL 3

Design approvals

EN 10204-3.1

Options

Display,
Customized parameterization,
Remote operation via SmartBlue App using BluetoothВ®,
Gas-tight feed through,
PWIS free

Application limits

Process temp. > 130 В°C (266 В°F) -> FMR62
Very aggressive media -> FMR62
Strong turbulences and foam, stilling well and bypass -> FMR5x, FMP5x

Comments

No comments yet

Write a comment