Endress+Hauser Micropilot FMR20
Radar measurement Time-of-Flight
+/- 2 mm (0,08")
Process temperature-40...+80В°C (-40...+176В°F)
Process pressure / max. overpressure limit-1...3 bar (-14,5...43 psi)
Max. measurement distanceDN40: 15 m (49.2 ft),
DN80: 20 m (65.6 ft)
PVDF, PBT
- Overview
- Comments
Level measurement of liquids and solids in all industries.
Measuring principleLevel radar
Characteristic / ApplicationWater & Wastewater (e.g. basins / channels / rivers / dams / lift stations / storm water basins / pump control)
Utility applications in all industries
Storage tanks
BluetoothВ® commissioning,
Operation and maintenance SmartBlue App
2-wire (HART, 4...20 mA, Modbus),
BluetoothВ® wireless technology and App (optional)
K-band (~26 GHz)
Accuracy+/- 2 mm (0,08")
Ambient temperature-40...+80В°C (-40...+176В°F)
Process temperature-40...+80В°C (-40...+176В°F)
Process pressure / max. overpressure limit-1...3 bar (-14,5...43 psi)
Main wetted partsPVDF, PBT
Process connectionThread:
G1", NPT1"; G1 1/2", NPT1 1/2", G2", NPT2",
Flange:
UNI DN80....DN150 (3"...6")
DN40: 15 m (49.2 ft),
DN80: 20 m (65.6 ft)
4...20mA HART
Modbus
BluetoothВ® wireless technology
ATEX, CSA C/US, IEC Ex, NEPSI, EAC, JPN Ex, INMETRO
OptionsRemote operation via SmartBlue App using BluetoothВ®,
Remote HART indicator RIA15 in order structure,
Flooding protection tube,
Different mounting possibilities
FMR5x;
Ammoniacal gas phase:
FMR54 in stilling well;
Strong build-up formation:
FMR54 with air purge;
Only PTFE resistant:
FMR52;
Custody transfer measurement:
FMR5xx or NMR8x
Level radar solid
Characteristic / ApplicationFor simple applications:
Reliable non-contact level measurements in silos or storage tanks for bulk solids
BluetoothВ® commissioning,
Operation and maintenance SmartBlue App
2-wire (HART, 4...20 mA, Modbus),
BluetoothВ® wireless technology and App (optional)
K-band (~26 GHz)
Antenna80 mm/ 3"
AccuracyLiquids: +/- 2 mm (0,08")
Solids. +/- 5 mm (0.2")
-40...+80В°C (-40...+176В°F)
Process temperature-40...+80В°C (-40...+176В°F)
Process pressure / max. overpressure limit-1...3 bar (-14,5...43 psi)
Main wetted partsPVDF, PBT
Process connectionThread:
G1", NPT1";
Flange:
UNI DN80....DN150 (3"...6")
Liquids: 20 m (66.6 ft)
Solids: 10 m (32.8 ft)
4...20 mA HART
Modbus
BluetoothВ® wireless technology
Remote operation via SmartBlue App using BluetoothВ®,
Remote HART indicator RIA15 in order structure,
Flooding protection tube,
Different mounting possibilities
DK < 2
Reduction of the max. possible measuring range through:
Media with poor reflection properties
Angle of repose
Extremely loose surfaces of bulk solids, e.g. bulk solids with low bulk weight for pneumatic filling
Build-up, above all of moist products
Comments
No comments yet