Endress+Hauser Gammapilot FMG50
Radiometric level and density measurement

Endress+Hauser Gammapilot FMG50
Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Max. measurement distance

Unlimited measuring range,
Cascade

Accuracy

+/-1%

Main wetted parts

Non-contact

Item Number: Gammapilot FMG50
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Compact transmitter for point level detection, continuous level, interface and density measurement.

Measuring principle

Radiometric

Characteristic / Application

Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique

Specialities

Heartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning, operation and maintenance with the SmartBlue App

Supply / Communication

2-wire loop powered

Accuracy

+/-1%

Ambient temperature

-40 В°C...+80 В°C,
(-40 В°F...+176 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Sensor length

PVT scintillator
400 mm...3000 mm,
>3000 mm cascade mode

Max. measurement distance

Unlimited measuring range,
Cascade

Communication

4...20 mA HART

Certificates / Approvals

ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex

Safety approvals

Overfill protection WHG
SIL 2/3

Design approvals

EN 10204-3.1

Options

Display

Components

Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61

Measuring principle

Radiometric Limit

Characteristic / Application

Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique

Specialities

Heartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning, operation and maintenance with the SmartBlue App

Supply / Communication

2-wire loop powered

Ambient temperature

-40 В°C...+80 В°C,
(-40 В°F...+176 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Sensor length

PVT scintillator:
200 mm...400 mm,
NAI scintillator:
50 x 50 mm,
50 x 100 mm

Communication

4...20 mA HART

Certificates / Approvals

ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex

Safety approvals

Overfill protection WHG
SIL 2/3

Design approvals

EN 10204-3.1

Options

Display

Components

Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61

Measuring principle

Radiometric Density

Characteristic / Application

Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique

Supply / Communication

2-wire loop powered

Ambient temperature

-40 В°C...+80 В°C,
(-40 В°F...+176 В°F)

Process temperature

Any

Process pressure absolute

Any

Wetted parts

Non-contact

Sensor length

PVT scintillator:
200 mm...400 mm,
NAI scintillator:
50 x 50 mm,
50 x 100 mm

Output

4...20 mA HART

Certificates / Approvals

ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex

Options

Display

Specialities

Heartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning, operation and maintenance with the SmartBlue App

Components

Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61

Measuring principle

Radiometric

Characteristic / Application

Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique

Interface measurement

Interfaces liquid / liquid also with emulsion layers
Interfaces liquid / solid

Specialities

Heartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning, operation and maintenance with the SmartBlue App

Supply / Communication

2-wire loop powered

Accuracy

+/-1%

Ambient temperature

-40 В°C...+80 В°C,
(-40 В°F...+176 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Sensor length

PVT scintillator
400 mm...3000 mm,
>3000 mm cascade mode

Max. measurement distance

Unlimited measuring range,
Cascade

Communication

4...20 mA HART

Certificates / Approvals

ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex

Safety approvals

Overfill protection WHG
SIL 2/3

Design approvals

EN 10204-3.1

Options

Display

Components

Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61

Measuring principle

Radiometric Limit

Characteristic / Application

Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique

Specialities

Heartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning, operation and maintenance with the SmartBlue App

Supply / Communication

2-wire loop powered

Ambient temperature

-40 В°C...+80 В°C,
(-40 В°F...+176 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Sensor length

PVT scintillator:
200 mm...400 mm,
NAI scintillator:
50 x 50 mm,
50 x 100 mm

Communication

4...20 mA HART

Certificates / Approvals

ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex

Safety approvals

Overfill protection WHG
SIL 2/3

Design approvals

EN 10204-3.1

Options

Display

Components

Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61

Comments

No comments yet

Write a comment