Endress+Hauser Gammapilot FMG50
Radiometric level and density measurement
Any
Process pressure absolute / max. overpressure limitAny
Max. measurement distanceUnlimited measuring range,
Cascade
+/-1%
Main wetted partsNon-contact
- Overview
- Comments
Compact transmitter for point level detection, continuous level, interface and density measurement.
Measuring principleRadiometric
Characteristic / ApplicationCompact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning, operation and maintenance with the SmartBlue App
2-wire loop powered
Accuracy+/-1%
Ambient temperature-40 В°C...+80 В°C,
(-40 В°F...+176 В°F)
Any
Process pressure absolute / max. overpressure limitAny
Main wetted partsNon-contact
Process connectionNon-contact
Sensor lengthPVT scintillator
400 mm...3000 mm,
>3000 mm cascade mode
Unlimited measuring range,
Cascade
4...20 mA HART
Certificates / ApprovalsATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
Safety approvalsOverfill protection WHG
SIL 2/3
EN 10204-3.1
OptionsDisplay
ComponentsIsotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
Radiometric Limit
Characteristic / ApplicationCompact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning, operation and maintenance with the SmartBlue App
2-wire loop powered
Ambient temperature-40 В°C...+80 В°C,
(-40 В°F...+176 В°F)
Any
Process pressure absolute / max. overpressure limitAny
Main wetted partsNon-contact
Process connectionNon-contact
Sensor lengthPVT scintillator:
200 mm...400 mm,
NAI scintillator:
50 x 50 mm,
50 x 100 mm
4...20 mA HART
Certificates / ApprovalsATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
Safety approvalsOverfill protection WHG
SIL 2/3
EN 10204-3.1
OptionsDisplay
ComponentsIsotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
Radiometric Density
Characteristic / ApplicationCompact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique
2-wire loop powered
Ambient temperature-40 В°C...+80 В°C,
(-40 В°F...+176 В°F)
Any
Process pressure absoluteAny
Wetted partsNon-contact
Sensor lengthPVT scintillator:
200 mm...400 mm,
NAI scintillator:
50 x 50 mm,
50 x 100 mm
4...20 mA HART
Certificates / ApprovalsATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
OptionsDisplay
SpecialitiesHeartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning, operation and maintenance with the SmartBlue App
Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
Radiometric
Characteristic / ApplicationCompact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique
Interfaces liquid / liquid also with emulsion layers
Interfaces liquid / solid
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning, operation and maintenance with the SmartBlue App
2-wire loop powered
Accuracy+/-1%
Ambient temperature-40 В°C...+80 В°C,
(-40 В°F...+176 В°F)
Any
Process pressure absolute / max. overpressure limitAny
Main wetted partsNon-contact
Process connectionNon-contact
Sensor lengthPVT scintillator
400 mm...3000 mm,
>3000 mm cascade mode
Unlimited measuring range,
Cascade
4...20 mA HART
Certificates / ApprovalsATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
Safety approvalsOverfill protection WHG
SIL 2/3
EN 10204-3.1
OptionsDisplay
ComponentsIsotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
Radiometric Limit
Characteristic / ApplicationCompact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
BluetoothВ® commissioning, operation and maintenance with the SmartBlue App
2-wire loop powered
Ambient temperature-40 В°C...+80 В°C,
(-40 В°F...+176 В°F)
Any
Process pressure absolute / max. overpressure limitAny
Main wetted partsNon-contact
Process connectionNon-contact
Sensor lengthPVT scintillator:
200 mm...400 mm,
NAI scintillator:
50 x 50 mm,
50 x 100 mm
4...20 mA HART
Certificates / ApprovalsATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
Safety approvalsOverfill protection WHG
SIL 2/3
EN 10204-3.1
OptionsDisplay
ComponentsIsotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
Comments
No comments yet