Endress+Hauser Source Container FQG66
Radiometric Level and density

Endress+Hauser Source Container FQG66
Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Item Number: Source Container FQG66
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Radiation source container with sliding source support rod for manual or pneumatic on/off switching.

Measuring principle

Radiometric

Characteristic / Application

Source container
Emission angle: 40 / 20 degrees
435kg

Specialities

Control area calculation with Applicator

Ambient temperature

-55 В°C...+100 В°C
(-67 В°F...+212 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Measuring principle

Radiometric Density

Characteristic / Application

Source container
Emission angle: 5/ 20 / 40 degrees
435kg

Ambient temperature

-55 В°C...+100 В°C
(-67 В°F...+212 В°F)

Process temperature

Any

Process pressure absolute

Any

Wetted parts

Non-contact

Hygienic

Non-contact

Specialities

Control area calculation with Applicator

Measuring principle

Radiometric

Characteristic / Application

Source container
Emission angle: 40 / 20 degrees
435kg

Specialities

Sliding source support rod for manual or pneumatic on/ off switching

Ambient temperature

-55 В°C...+100 В°C
(-67 В°F...+212 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Measuring principle

Radiometric Limit

Characteristic / Application

Source container
Emission angle: 5 degrees
435kg

Specialities

Control area calculation with Applicator

Ambient temperature

-55 В°C...+100 В°C
(-67 В°F...+212 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non- contact

Process connection

Non- contact

Process connection hygienic

Non- contact

Measuring principle

Radiometric Limit

Characteristic / Application

Source container
Emission angle: 5 degrees
Approximately 435 kg

Specialities

Control area calculation with Applicator

Ambient temperature

-55 В°C ... +100 В°C
(-67 В°F ...+212 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non- contact

Process connection

Non- contact

Process connection hygienic

Non- contact

Comments

No comments yet

Write a comment