Endress+Hauser Source Container FQG62
Radiometric Level/density measurement

Endress+Hauser Source Container FQG62
Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Item Number: Source Container FQG62
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Radiation source container with source holder for manual or pneumatic switch-on/switch-off.

Measuring principle

Radiometric Limit

Characteristic / Application

Source container
Emission angle: 5 degrees
Approximately 87kg

Specialities

Control area calculation with Applicator

Ambient temperature

-40 В°C...+200 В°C
(-40 В°F...+392 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Certificates / Approvals

ATEX, GOST

Measuring principle

Radiometric

Characteristic / Application

Source container
Emission angle: 40 / 20 degrees
Approximately 87kg

Specialities

Control area calculation with Applicator

Ambient temperature

-40 В°C...+200 В°C
(-40 В°F ...+392 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Certificates / Approvals

ATEX, GOST

Measuring principle

Radiometric Limit

Characteristic / Application

Source container
Emission angle: 5 degrees
Approximately 87kg

Specialities

Control area calculation with Applicator

Ambient temperature

-40 В°C...+200 В°C
(-40 В°F...+392 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Certificates / Approvals

ATEX, GOST

Measuring principle

Radiometric

Characteristic / Application

Source container
Emission angle: 40 / 20 degrees
Approximately 87kg

Specialities

Manual or pneumatic switch-on/ switch-off

Ambient temperature

-40 В°C...+200 В°C
(-40 В°F...+392 В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Certificates / Approvals

ATEX, GOST

Measuring principle

Radiometric Density

Characteristic / Application

Source container
Emission angle: 5/ 20/ 40 degrees
87kg

Ambient temperature

-20 В°C...+200 В°C
(-40 В°F...+392 В°F)

Process temperature

Any

Process pressure absolute

Any

Wetted parts

Non-contact

Hygienic

Non-contact

Specialities

Control area calculation with Applicator

Comments

No comments yet