Endress+Hauser Gammapilot FTG20
Radiometric Point level detection

Endress+Hauser Gammapilot FTG20
Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Min. density of medium

Any

Min. conductivity of medium

Any

Item Number: Gammapilot FTG20
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Geiger-Mueller counter for point level detection with separate transmitter.

Measuring principle

Radiometric Limit

Characteristic / Application

Radiometric Transmitter with 1 to 3 Geiger-MГјller counters for contactless measurement in liquids, sludge or suspensions under exteme process conditions

Specialities

Calculation and sizing with Applicator

Supply / Communication

Relay DPDT:
19...253VAC, 19...55VDC
8/16mA:
11...36VDC, 11..30VDC (Exia)

Ambient temperature

Relay DPDT:
19...253VAC, 19...55VDC
8/16mA:
11...36VDC, 11..30VDC (Exia)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Min. density of medium

Any

Min. conductivity of medium

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Process connection hygienic

Non-contact

Sensor length

140 mm (5.5")

Communication

Relay DPDT
8/16mA
4...20mA

Certificates / Approvals

ATEX, CSA, CSA C/US, IEC Ex, NEPSI, EAC

Options

Sensitivity:
1x Geiger- counter: 1-8uSv/h,
2x Geiger- counter: 0,5-4uSv/h
3x Geiger- counter: 0,3-2,7uSv/h
Cooling jacket
Transmitter with compartment for conduit

Components

Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, QG2000

Measuring principle

Radiometric Limit

Characteristic / Application

Radiometric Transmitter with 1 to 3 Geiger-MГјller counters for contactless measurement in solids under exteme process conditions

Specialities

Calculation and sizing with Applicator

Supply / Communication

Relay DPDT:
19...253VAC, 19...55VDC
8/16mA:
11...36VDC, 11..30VDC (Exia)

Ambient temperature

-40...70В°C,
(-40...158В°F),
With cooling jacket:
0...120В°C
(32...248В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Min. density of medium

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Process connection hygienic

Non-contact

Sensor length

140 mm (5.5")

Communication

Relay DPDT
8/16mA
4...20mA

Certificates / Approvals

ATEX, CSA C/US, IEC Ex, NEPSI, EAC

Options

Sensitivity:
1x Geiger- counter: 1-8uSv/h,
2x Geiger- counter: 0,5-4uSv/h
3x Geiger- counter: 0,3-2,7uSv/h
Cooling jacket
Transmitter with compartment for conduit

Components

Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, QG2000

Comments

No comments yet

Write a comment