Endress+Hauser TLSR2
RTD-Assembly S.A. Style

Endress+Hauser TLSR2
Item Number: TLSR2
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Measuring principle

Resistance Temperature Detector

Characteristic / Application

S.A. Style
Cable sensor
universal range of application
usable with or without a thermowell

Thermowell / protection tube

to use with or without thermowell (can be ordered separately)

Insert / probe

mineral insulated (MI), flexible

Max. immersion length on request

up to 2.000 mm (78,74'')

Material protection tube/ thermowell

1.4401 (316)

Optional coating

Not defined

Process connection

Fixed thread:
NPT 1/4"
NPT 1/2"
G1/4"
G1/2"
Adjustable compression fitting:
NPT 1/8"
NPT 1/4"
NPT 3/8"
NPT 1/2"
G1/8"
G1/4"
G3/8"
G1/2"

Tip shape

rounded
flat

Operating temperature range

PT 100:
-200 ...600 В°C
(-328 ...1.112 В°F)

Max. process pressure (static)

at 20 В°C: 10 bar (150 psi) without thermowell

Accuracy

class A according to IEC 60751
Band 5 (1/10 DIN)

Response time

depending on configuration

Integration head transmitter

no

Certification

EN10204 3.1 Material traceability

Comments

No comments yet