Endress+Hauser Proservo NMS83
Servo tank gauging instrument

Endress+Hauser Proservo NMS83
Accuracy

up to 0.4 mm

Process temperature

-200В°C...200В°C
(-328В°F...392В°F)

Process pressure absolute / max. overpressure limit

6 bar abs

Max. measurement distance

22 m (72 ft)

Main wetted parts

316L, AlloyC276, PTFE

Item Number: Proservo NMS83
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

High precision servo measurement for liquid level, interface and density for hygienic applications.

Measuring principle

Servo / Float Tank Gauging

Characteristic / Application

Servo Tank Gauging: High precision measurement for liquid level,
interface, spot density and density profile for hygienic applications

Supply / Communication

85-264VAC

Ambient temperature

Standard:
-40В°C...60В°C
(-40В°F...140В°F)
For calibration to regulatory
standards:
-25В°C...55В°C
(-13В°F...131В°F)

Process temperature

-200В°C...200В°C
(-328В°F...392В°F)

Process pressure absolute

6 bar abs

Wetted parts

316L, AlloyC276, PTFE

Output

Outputs:
Fieldbus: Modbus RS485, V1, HART
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active)

Certificates / Approvals

ATEX, FM, IEC Ex, NEPSI, EAC

Options

Redundant fieldbus
Weather protection cover
CIP (Cleaning in Place)
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection

Specialities

Custody transfer level measurement
Interface measurement
Spot density, density profile measurement

Measuring range

22 m (72 ft)

Other approvals and certificates

EN 10204-3.1
NACE MR0175, MR0103
OIML, NMi, PTB

Measuring principle

Servo / Float Tank Gauging

Characteristic / Application

Servo Tank Gauging: High precision measurement for liquid level,
interface, spot density and density profile for hygienic applications

Specialities

Custody transfer level measurement
Interface measurement
Spot density, density profile measurement

Supply / Communication

85-264VAC

Accuracy

up to 0.4 mm

Ambient temperature

Standard:
-40В°C...60В°C
(-40В°F...140В°F)
For calibration to regulatory
standards:
-25В°C...55В°C
(-13В°F...131В°F)

Process temperature

-200В°C...200В°C
(-328В°F...392В°F)

Process pressure absolute / max. overpressure limit

6 bar abs

Main wetted parts

316L, AlloyC276, PTFE

Process connection

Flange:
DN80/3" / DN150/6"

Max. measurement distance

22 m (72 ft)

Communication

Outputs:
Fieldbus: Modbus RS485, V1, HART
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active)

Certificates / Approvals

ATEX, FM, IEC Ex, NEPSI, EAC

Safety approvals

Overfill protection WHG
SIL

Design approvals

EN 10204-3.1
NACE MR0175, MR0103

Metrological approvals and certificates

OIML, NMi, PTB

Options

Redundant fieldbus
Weather protection cover
CIP (Cleaning in Place)
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection

Application limits

Stilling well or guide wires for turbulent
application
Recommend PTFE displacer for high
viscosity application
Interface measurement requires min. difference of 0.100 g/ml
between layers