Endress+Hauser SS2000
H2O or CO2 gas analyzer
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature
CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2
- Overview +
- Comments +
Extremely reliable measurement of H2O or CO2 in natural gas.
Measuring principleTDLAS
Product HeadlineSingle channel gas analyzer for moisture (H2O) in the natural gas industry. The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.
Channels1
Analyte and Measurement rangesH2O (Moisture): 0-100 to 0-5000 ppmv
Measured VariablesConcentration
Moisture Dew Point
Cell Pressure
Cell Temperature
-20 to 50В°C (-4 to 122В°F)
Operating Pressure rangeInlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara
316L Stainless Steel
FKM O-Rings
Glass
100-240 VAC, 50-60 Hz
OR
9-16 VDC or 18-32 VDC - optional
1 Amp maximum @ 120 VAC
1.6 Amp @ 24VDC, 3.2 Amp @ 12 VDC
Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s)
Electronics: 304 Stainless Steel (Class I Div 2)
Electronics: Cast Aluminum (Class I Div 1)
Sample System Panel: Anodized aluminum
CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2
Type 3R (Class I Div 2)
Type 4 (Class I Div 1)
TDLAS
Product HeadlineSingle channel gas analyzer for carbon dioxide (CO2) in the natural gas industry. The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.
Channels1
Analyte and Measurement rangesCO2 (Carbon Dioxide): 0-5% to 0-50%
Measured VariablesConcentration
Cell Pressure
Cell Temperature
-20 to 50В°C (-4 to 122В°F)
Operating Pressure rangeInlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara
316L Stainless Steel
FKM O-Rings
Glass
100-240 VAC, 50-60 Hz
OR
9-16 VDC or 18-32 VDC - optional
1 Amp maximum @ 120 VAC
1.6 Amps @ 24VDC, 3.2 Amps @ 12 VDC
Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s)
Electronics: 304 Stainless Steel (Class I Div 2)
Electronics: Cast Aluminum (Class I Div 1)
Sample System Panel: Anodized aluminum
CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2
Type 3R (Class I Div 2)
Type 4 (Class I Div 1)
Buy Endress+Hauser SS2000 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com provides top-quality industrial control components. Our online catalog features a wide range of products to meet your specific requirements. Enjoy the convenience of consolidated shipments and competitive pricing. Join our satisfied customers who rely on us for their automation solutions.
Comments
No comments yet