Endress+Hauser SS2000
H2O or CO2 gas analyzer

Endress+Hauser SS2000
Measured Variables

Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature

Hazardous area approvals

CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2

Item Number: SS2000
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Extremely reliable measurement of H2O or CO2 in natural gas.

Measuring principle

TDLAS

Product Headline

Single channel gas analyzer for moisture (H2O) in the natural gas industry. The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.

Channels

1

Analyte and Measurement ranges

H2O (Moisture): 0-100 to 0-5000 ppmv

Measured Variables

Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature

Ambient Temperature range

-20 to 50В°C (-4 to 122В°F)

Operating Pressure range

Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara

Analyzer Wetted materials

316L Stainless Steel
FKM O-Rings
Glass

Power supply

100-240 VAC, 50-60 Hz
OR
9-16 VDC or 18-32 VDC - optional
1 Amp maximum @ 120 VAC
1.6 Amp @ 24VDC, 3.2 Amp @ 12 VDC

Communication

Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s)

Housing materials

Electronics: 304 Stainless Steel (Class I Div 2)
Electronics: Cast Aluminum (Class I Div 1)
Sample System Panel: Anodized aluminum

Hazardous area approvals

CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2

Degree of protection

Type 3R (Class I Div 2)
Type 4 (Class I Div 1)

Measuring principle

TDLAS

Product Headline

Single channel gas analyzer for carbon dioxide (CO2) in the natural gas industry. The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.

Channels

1

Analyte and Measurement ranges

CO2 (Carbon Dioxide): 0-5% to 0-50%

Measured Variables

Concentration
Cell Pressure
Cell Temperature

Ambient Temperature range

-20 to 50В°C (-4 to 122В°F)

Operating Pressure range

Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara

Analyzer Wetted materials

316L Stainless Steel
FKM O-Rings
Glass

Power supply

100-240 VAC, 50-60 Hz
OR
9-16 VDC or 18-32 VDC - optional
1 Amp maximum @ 120 VAC
1.6 Amps @ 24VDC, 3.2 Amps @ 12 VDC

Communication

Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s)

Housing materials

Electronics: 304 Stainless Steel (Class I Div 2)
Electronics: Cast Aluminum (Class I Div 1)
Sample System Panel: Anodized aluminum

Hazardous area approvals

CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2

Degree of protection

Type 3R (Class I Div 2)
Type 4 (Class I Div 1)

Comments

No comments yet

Write a comment