Endress+Hauser SS2100
Gas analyzer

Endress+Hauser SS2100
Measured Variables

Concentration
Cell Pressure
Cell Temperature

Hazardous area approvals

CSA Class I, Division 2
CSA Class I, Zone 2

Item Number: SS2100
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Exceptionally reliable for measuring trace gas components.

Measuring principle

TDLAS

Product Headline

An advanced gas analyzer for hydrogen sulfide (H2S) measurement. The SS2100 uses Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.

Channels

1

Analyte and Measurement ranges

H2S (Hydrogen Sulfide): 0-10 to 0-1000 ppmv; 0-5000 ppmv to 0-5%

Measured Variables

Concentration
Cell Pressure
Cell Temperature

Ambient Temperature range

-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)

Operating Pressure range

Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 800-1200 mbara or 950-1700 mbara (optional)

Analyzer Wetted materials

316L Stainless Steel
FKM O-Rings
Glass

Power supply

120 or 240 VAC В±10%, 50-60 Hz, 300W
(18-24 VDC - optional for electronics only)
3 Amps max @ 120 VAC , 1.5 Amps max @ 240 VAC Hz

Communication

Analog Output: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request

Housing materials

Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel

Hazardous area approvals

CSA Class I, Division 2
CSA Class I, Zone 2

Degree of protection

IP66, Type 4X

Measuring principle

TDLAS

Product Headline

An advanced gas analyzer for moisture (H2O) measurement. The SS2100 uses Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.

Channels

1

Analyte and Measurement ranges

H2O (Moisture): 0-10 to 0-100 ppmv; 0-50 to 0-5000 ppmv

Measured Variables

Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature

Ambient Temperature range

-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)

Operating Pressure range

Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 800-1200 mbara or 950-1700 mbara (optional)

Analyzer Wetted materials

316L Stainless Steel
FKM O-Rings
Glass

Power supply

120 or 240 VAC В±10%, 50-60 Hz, 300W
(18-24 VDC - optional for electronics only)
3 Amps max @ 120 VAC , 1.5 Amps max @ 240 VAC Hz

Communication

Analog Output: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request

Housing materials

Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel

Hazardous area approvals

CSA Class I, Division 2
CSA Class I, Zone 2

Degree of protection

IP66, Type 4X

Measuring principle

TDLAS

Product Headline

An advanced gas analyzer for carbon dioxide (CO2) measurement. The SS2100 uses Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.

Channels

1

Analyte and Measurement ranges

CO2 (Carbon Dioxide): 0-10 to 0-1000 ppmv; 0-5000 ppmv to 0-5%

Measured Variables

Concentration
Cell Pressure
Cell Temperature

Ambient Temperature range

-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)

Operating Pressure range

Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 800-1200 mbara or 950-1700 mbara (optional)

Analyzer Wetted materials

316L Stainless Steel
FKM O-Rings
Glass

Power supply

120 or 240 VAC В±10%, 50-60 Hz, 300W
(18-24 VDC - optional for electronics only)
3 Amps max @ 120 VAC , 1.5 Amps max @ 240 VAC Hz

Communication

Analog Output: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request

Housing materials

Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel

Hazardous area approvals

CSA Class I, Division 2
CSA Class I, Zone 2

Degree of protection

IP66, Type 4X

Measuring principle

TDLAS

Product Headline

An advanced gas analyzer for ammonia (NH3) measurement. The SS2100 uses Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.

Channels

1

Analyte and Measurement ranges

NH3 (Ammonia): 0-5 ppmv

Measured Variables

Concentration
Cell Pressure
Cell Temperature

Ambient Temperature range

-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)

Operating Pressure range

Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 800-1200 mbara or 950-1700 mbara (optional)

Analyzer Wetted materials

316L Stainless Steel
FKM O-Rings
Glass

Power supply

120 or 240 VAC В±10%, 50-60 Hz, 300W
(18-24 VDC - optional for electronics only)
3 Amps max @ 120 VAC , 1.5 Amps max @ 240 VAC Hz

Communication

Analog Output: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request

Housing materials

Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel

Hazardous area approvals

CSA Class I, Division 2
CSA Class I, Zone 2

Degree of protection

IP66, Type 4X

Measuring principle

TDLAS

Product Headline

An advanced gas analyzer for acetylene (C2H2) measurement. The SS2100 uses Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.

Channels

1

Analyte and Measurement ranges

C2H2 (Acetylene): 0-5; 0-3000 ppmv

Measured Variables

Concentration
Cell Pressure
Cell Temperature

Ambient Temperature range

-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)

Operating Pressure range

Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 800-1200 mbara or 950-1700 mbara (optional)

Analyzer Wetted materials

316L Stainless Steel
FKM O-Rings
Glass

Power supply

120 or 240 VAC В±10%, 50-60 Hz, 300W
(18-24 VDC - optional for electronics only)
3 Amps max @ 120 VAC , 1.5 Amps max @ 240 VAC Hz

Communication

Analog Output: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request

Housing materials

Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel

Hazardous area approvals

CSA Class I, Division 2
CSA Class I, Zone 2

Degree of protection

IP66, Type 4X

Measuring principle

TDLAS

Product Headline

Advanced multi-channel gas analyzer for hydrogen sulfide (H2S) and moisture (H2O), also known as a 2-Pack. The SS2100 uses Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.

Channels

2

Analyte and Measurement ranges

H2S (Hydrogen Sulfide): 0-10 to 0-1000 ppmv
H2O (Moisture): 0-100 to 0-5000 ppmv

Measured Variables

Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature

Ambient Temperature range

-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)

Operating Pressure range

Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 800-1200 mbara or 950-1700 mbara (optional)

Analyzer Wetted materials

316L Stainless Steel
FKM O-Rings
Glass

Power supply

120 or 240 VAC В±10%, 50-60 Hz, 300W
(18-24 VDC - optional for electronics only)
3 Amps max @ 120 VAC , 1.5 Amps max @ 240 VAC Hz

Communication

Analog Output: Four 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (H2O)
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs (H2S): 2, Flow Alarm, Validation Request
Digital Outputs (H2O): 2, Concentration Alarm, General Fault

Housing materials

Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel

Hazardous area approvals

CSA Class I, Division 2
CSA Class I, Zone 2

Degree of protection

IP66, Type 4X

Measuring principle

TDLAS

Product Headline

Advanced multi-channel gas analyzer for hydrogen sulfide (H2S) and carbon dioxide (CO2), also known as a 2-Pack. The SS2100 uses Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.

Channels

2

Analyte and Measurement ranges

H2S (Hydrogen Sulfide): 0-10 to 0-1000 ppmv
CO2 (Carbon Dioxide): 0-5000 ppmv to 0-5%

Measured Variables

Concentration
Cell Pressure
Cell Temperature

Ambient Temperature range

-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)

Operating Pressure range

Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 800-1200 mbara or 950-1700 mbara (optional)

Analyzer Wetted materials

316L Stainless Steel
FKM O-Rings
Glass

Power supply

120 or 240 VAC В±10%, 50-60 Hz, 300W
(18-24 VDC - optional for electronics only)
3 Amps max @ 120 VAC , 1.5 Amps max @ 240 VAC Hz

Communication

Analog Output: Four 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (CO2)
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs (H2S): 2, Flow Alarm, Validation Request
Digital Outputs (CO2): 2, Concentration Alarm, General Fault

Housing materials

Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel

Hazardous area approvals

CSA Class I, Division 2
CSA Class I, Zone 2

Degree of protection

IP66, Type 4X

Measuring principle

TDLAS

Product Headline

Advanced multi-channel gas analyzer for hydrogen sulfide (H2S), moisture (H2O), and carbon dioxide (CO2), also known as a 3-Pack. The SS2100 uses Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.

Channels

3

Analyte and Measurement ranges

H2S (Hydrogen Sulfide): 0-10 to 0-1000 ppmv
H2O (Moisture): 0-100 to 0-5000 ppmv
CO2 (Carbon Dioxide): 0-5000 ppmv to 0-5%

Measured Variables

Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature

Ambient Temperature range

-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)

Operating Pressure range

Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 800-1200 mbara or 950-1700 mbara (optional)

Analyzer Wetted materials

316L Stainless Steel
FKM O-Rings
Glass

Power supply

120 or 240 VAC В±10%, 50-60 Hz, 300W
(18-24 VDC - optional for electronics only)
3 Amps max @ 120 VAC , 1.5 Amps max @ 240 VAC Hz

Communication

Analog Output: Four 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (H2O/CO2)
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs (H2S): 2, Flow Alarm, Validation Request
Digital Outputs (H2O/CO2): 2, Concentration Alarm, General Fault

Housing materials

Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel

Hazardous area approvals

CSA Class I, Division 2
CSA Class I, Zone 2

Degree of protection

IP66, Type 4X