Endress+Hauser SS3000
Dual channel H2O or CO2 gas analyzer
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature
CSA Class I, Division 2
CSA Class I, Zone 2
- Overview +
- Comments +
Rapid response time and trustworthy H2O & CO2 measurements for the natural gas industry.
Measuring principleTDLAS
Product HeadlineDual channel gas analyzer for moisture (H2O) and carbon dioxide (CO2). The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.
Channels2
Analyte and Measurement rangesH2O (Moisture): 0-100 to 0-5000 ppmv
CO2 (Carbon Dioxide): 0-5% to 0-50%
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature
-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)
Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara
316L Stainless Steel
FKM O-Rings
Glass
100-240 VAC, 50-60 Hz
OR
9-16 VDC or 18-32 VDC - optional
1 Amp maximum @ 120 VAC
1.6 Amps @ 24 VDC, 3.2 Amps @ 12 VDC
Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Alarms: Four General Fault and Concentration Alarms via Modbus and Analog Output(s)
Electronics: 304 Stainless Steel
Sample System Panel: Anodized aluminum
CSA Class I, Division 2
CSA Class I, Zone 2
Type 3R
Measuring principleTDLAS
Product HeadlineDual channel gas analyzer for two moisture (H2O) channels. The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.
Channels2
Analyte and Measurement rangesH2O (Moisture): 0-100 to 0-5000 ppmv
Measured VariablesConcentration
Moisture Dew Point
Cell Pressure
Cell Temperature
-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)
Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara
316L Stainless Steel
FKM O-Rings
Glass
100-240 VAC, 50-60 Hz
OR
9-16 VDC or 18-32 VDC - optional
1 Amp maximum @ 120 VAC
1.6 Amps @ 24 VDC, 3.2 Amps @ 12 VDC
Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Alarms: Four General Fault and Concentration Alarms via Modbus and Analog Output(s)
Electronics: 304 Stainless Steel
Sample System Panel: Anodized aluminum
CSA Class I, Division 2
CSA Class I, Zone 2
Type 3R
Buy Endress+Hauser SS3000 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is your go-to source for industrial electrical parts. Our extensive product range includes various automation equipment, available for fast worldwide delivery. We guarantee high quality and competitive pricing. Make us your trusted partner for all your electrical supply needs.
Comments