Endress+Hauser SS3000e
Dual channel H2O or CO2 gas analyzer
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature
CSA Class I, Division 2
CSA Class I, Zone 2
- Overview +
- Comments +
Rapid response time and trustworthy H2O & CO2 measurements for the natural gas industry.
Measuring principleTDLAS
Product HeadlineDual channel gas analyzer for moisture (H2O) channels and carbon dioxide (CO2). The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream. Includes a heated enclosure for the sample conditioning system.
Channels2
Analyte and Measurement rangesH2O (Moisture): 0-100 to 0-5000 ppmv
CO2 (Carbon Dioxide): 0-5% to 0-50%
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature
-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)
Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara or 700-1700 mbara (optional)
316L Stainless Steel
FKM O-Rings
Glass
100-240 VAC, 50-60 HZ
OR
18-24 VDC - optional
1 Amp maximum @ 120 VAC, 1.6 Amps @ 24 VDC (unheated)
2 Amps maximum @ 120 VAC (heated)
Analog Output: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C - standard, RS485 and Ethernet - optional
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 2, General Fault and Concentration/Assignable Alarm
Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel
CSA Class I, Division 2
CSA Class I, Zone 2
Type 4X
Measuring principleTDLAS
Product HeadlineDual channel gas analyzer for two moisture (H2O) channels. The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream. Includes a heated enclosure for the sample conditioning system.
Channels2
Analyte and Measurement rangesH2O (Moisture): 0-100 to 0-5000 ppmv
Measured VariablesConcentration
Moisture Dew Point
Cell Pressure
Cell Temperature
-20 to 50В°C (-4 to 122В°F)
Optional: -10 to 60В°C (14 to 140В°F)
Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara or 700-1700 mbara (optional)
316L Stainless Steel
FKM O-Rings
Glass
100-240 VAC, 50-60 HZ
OR
18-24 VDC - optional
1 Amp maximum @ 120 VAC, 1.6 Amps @ 24 VDC (unheated)
2 Amps maximum @ 120 VAC (heated)
Analog Output: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C - standard, RS485 and Ethernet - optional
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 2, General Fault and Concentration/Assignable Alarm
Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel
CSA Class I, Division 2
CSA Class I, Zone 2
Type 4X
Buy Endress+Hauser SS3000e with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. offers comprehensive industrial automation solutions. With a wide selection of products and express delivery options, we meet your demands efficiently. Our commitment to quality and customer satisfaction sets us apart. Experience the difference with our reliable services.
Comments