Endress+Hauser Proline t-mass 65F
Thermal mass flowmeter

Endress+Hauser Proline t-mass 65F

Thermal Mass Flow Meter

Max. measurement error

Gas: 1.5% o.r. (10 to 100% o.f.s.), 0.15% o.f.s. (1 to 10% o.f.s.)

Item Number: Proline t-mass 65F
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Thermal mass flowmeter T-mass. Direct measurement of gas mass flow. Temperature value as output signal.

Robust flowmeter with adaptation to changing process conditions.

Measuring range

0.5 to 3750 kg/h (1.1 to 8250 lb/h)

Medium temperature range

-40 В°C to +100 В°C (-40 В°F to +212 В°F)

Max. process pressure

PN40 / Cl. 300 / 20K

Wetted materials

Transducer: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
Process connections: 1.4404 (316L/316)
Sensor body:
DN 15 to 25 (1/2"" to 1""): CF3M-A351
DN 40 to 100 (1-1/2"" to 4""): 1.4404 (316/316L)
Bushing: PEEK GF30, PVDF
O-ring seals: EPDM, Kalrez 6375, Viton FKM

Measuring principle

Thermal

Product headline

High-performing flowmeter with intelligent and dynamic adaptation to changing process conditions.
Measurement of gases and gas mixtures in small line sizes.

Sensor features

Plant safety high accuracy and repeatability for a wide range of utility and process gases. Cost-effective measurement easy installation, negligible pressure loss and maintenance-free.
Inline version: nominal diameter DN 15 to 100 (ВЅ to 4"). Process pressure up to PN 40, Class 300. High accuracy: В±1.5 % o.r. (10 to 100 % o.f.s.).

Transmitter features

Reliable flow trending multivariable measurement. Flexible device configuration to suit the application integrated "Gas Engine" functionality. For demanding applications user-definable gas mixtures, high repeatability and accuracy.
Device as compact or remote version. 4-20 mA HART, PROFIBUS PA/DP, Modbus RS485, FF. Worldwide approvals (Hazardous areas).

Nominal diameter range

DN 15 to 100 (1/2" to 4")

Wetted materials

Transducer: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
Process connections: 1.4404 (316L/316)
Sensor body:
DN 15 to 25 (1/2"" to 1""): CF3M-A351
DN 40 to 100 (1-1/2"" to 4""): 1.4404 (316/316L)
Bushing: PEEK GF30, PVDF
O-ring seals: EPDM, Kalrez 6375, Viton FKM

Measured variables

Mass flow, temperature, volume flow, energy flow

Max. measurement error

Gas: 1.5% o.r. (10 to 100% o.f.s.), 0.15% o.f.s. (1 to 10% o.f.s.)

Measuring range

0.5 to 3750 kg/h (1.1 to 8250 lb/h)

Max. process pressure

PN40 / Cl. 300 / 20K

Medium temperature range

-40 В°C to +100 В°C (-40 В°F to +212 В°F)

Ambient temperature range

-20 В°C to +60 В°C (-4 В°F to +140 В°F)
Optional: -40 В°C to +60 В°C (-40 В°F to +140 В°F)

Transmitter housing material

Transmitter housing:
Compact: powder coated die-cast aluminium
Wall-mount: powder coated die-cast aluminium
Remote field: powder coated die-cast aluminium
Connection housing (remote version): powder coated die-cast aluminium

Degree of protection

IP 67
NEMA 4x

Display/Operation

Liquid crystal: back-lit, two lines with 16 characters per line
Configuration via local display and operating tools possible

Outputs

4-20mA HART (active/passive selectable), pulse, frequency, status

Inputs

4-20mA, status input

Digital communication

HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485

Power supply

85 to 260 VAC, 45 to 65 Hz
20 to 55 VAC, 45 to 65 Hz
16 to 62 VDC

Hazardous area approvals

ATEX, FM, CSA, NEPSI

Product safety

CE, C-tick, EAC marking

Pressure approvals and certificates

PED, CRN

Hygienic approvals and certificates

Oxygen service (certified acc. To BS IEC 60877)

Comments

No comments yet

Write a comment