Endress+Hauser Proline t-mass B 150
Thermal mass flowmeter

Endress+Hauser Proline t-mass B 150

Thermal Mass Flow Meter

Max. measurement error

3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")

Item Number: Proline t-mass B 150
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Thermal mass flowmeter T-mass. Wide dynamic range of 150:1 and high sensitivity in the low flow region. Direct measurement of gas mass flow. Conversion of mass flow to volume flow under normal conditions without an additional calculator.

The flowmeter for cost-effective measurement and easy monitoring of utility gases.

Measuring principleMeasuring range

20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")

Medium temperature range

40 to +100 В°C (40 to +212 В°F)

Max. process pressure

20 bar g (290 psi g)

Wetted materials

Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G

Thermal

Product headline

The flowmeter for cost-effective measurement and easy monitoring of utility gases.
Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.

Sensor features

Optimal process monitoring easy measurement even at low pressures and flow velocities. Cost...effective measurement easy installation, negligible pressure loss and maintenance...free. Reliable flow trending multivariable measurement.
Insertion version for nominal diameter DN 80 to 1500 (3 to 60"). Installation and removal of sensor without process interruption. Easy installation.

Transmitter features

Fast and efficient commissioning guided operating menus. High plant availability self...diagnostics and error monitoring. Automatic recovery of data for servicing.
Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter.

Nominal diameter range

DN 80 to 1500 (3 to 60")

Wetted materials

Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G

Measured variables

Mass flow, temperature, corrected volume flow, FAD volume flow

Max. measurement error

3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")

Measuring range

20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")

Max. process pressure

20 bar g (290 psi g)

Medium temperature range

40 to +100 В°C (40 to +212 В°F)

Ambient temperature range

40 to +60 В°C (40 to +140 В°F)

Transmitter housing material

AlSi10Mg, coated

Degree of protection

IP66/67, type 4X enclosure

Display/Operation

4...line display with push Buttons
Configuration via local display and operating tools possible

Outputs

4...20 mA HART (active)
Pulse/frequency/switch output (passive)

Inputs

Status input

Digital communication

HART

Power supply

DC 18 to 30 V

Hazardous area approvals

ATEX, IECEx, cCSAus

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

Pressure approvals and certificates

CRN

Comments

No comments yet

Write a comment