Endress+Hauser T14
Explosion proof Pt100 thermometer, US style

Endress+Hauser T14
We ship to United States of America!
Accuracy

class A acc. to IEC 60751
class B acc. to IEC 60751

Response time

depending on configuration
63% rt = 20 s

Max. process pressure (static)

at 20 В°C: 500 bar (7.252 psi)
depends on configuration

Operating temperature range

PT100 WW:
-200 В°C ... 600 В°C
(-328 В°F ... 1.112 В°F)
PT100 TF:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)

Max. immersion length on request

up to 22.5" (571 mm)
others on request

Item Number: T14
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry.

Measuring principle

Resistance Temperature Detector

Characteristic / Application

Explosion Proof US style
modular temperature assembly
for heavy duty applications
flanged process connection
with extension
incl. thermowell

Thermowell / protection tube

bar stock (drilled)

Insert / probe

mineral insulated (MI), flexible
PTFE-insulated, rigid

Outer diameter protection tube / Insert

7/8'' (22,23 mm)
17/16'' (26,99 mm)

Max. immersion length on request

up to 22.5" (571 mm)
others on request

Material protection tube/ thermowell

316/316L
others on request

Optional coating

Available on request

Process connection

flange:
ASME 1" 150 RF (B16.5)
ASME 1" 300 RF (B16.5)
ASME 1" 600 RF (B16.5)
ASME 1" 900/1500 RF (B16.5)
ASME 1,5" 150 RF (B16.5)
ASME 1,5" 300 RF (B16.5)
ASME 1,5" 600 RF (B16.5)
ASME 1,5" 900/1500 RF (B16.5)
ASME 2" 150 RF (B16.5)
ASME 2" 300 RF (B16.5)
ASME 2" 600 RF (B16.5)
ASME 2" 900/1500 RF (B16.5)

Tip shape

straight
tapered

Surface roughness Ra

32 Ојin. (0.80 Ојm)

Operating temperature range

PT100 WW:
-200 В°C ... 600 В°C
(-328 В°F ... 1.112 В°F)
PT100 TF:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)

Max. process pressure (static)

at 20 В°C: 500 bar (7.252 psi)
depends on configuration

Accuracy

class A acc. to IEC 60751
class B acc. to IEC 60751

Response time

depending on configuration
63% rt = 20 s

Integration head transmitter

yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

FM XP
CSA XP
FM/CSA XP
CSA GP

Certification

SIL (transmitter only)

Comments

No comments yet