Endress+Hauser T15 Explosion proof RTD thermometer, US style


class A acc. to IEC 60751
class B acc. to IEC 60751
63% rt = 3 s
Max. process pressure (static)Not applicable
Operating temperature rangePT100 WW:
-200 В°C ... 600 В°C
(-328 В°F ... 1.112 В°F)
PT100 TF:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)
up to 100" (2540 mm)
others on request
- Overview
- Datasheet
- Alternative numbers
- Comments
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry.
Measuring principleResistance Temperature Detector
Characteristic / ApplicationExplosion Proof US style
modular temperature assembly
for heavy duty applications
with extension
to be used with existing thermowell
to be used with thermowell
Insert / probemineral insulated (MI), flexible
PTFE-insulated, rigid
Not applicable
Max. immersion length on requestup to 100" (2540 mm)
others on request
Sensor sheath
316/316L
Not defined
Process connectionmale thread:
NPT1/2"
straight
Surface roughness RaNot defined
Operating temperature rangePT100 WW:
-200 В°C ... 600 В°C
(-328 В°F ... 1.112 В°F)
PT100 TF:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)
Not applicable
Accuracyclass A acc. to IEC 60751
class B acc. to IEC 60751
63% rt = 3 s
Integration head transmitteryes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsFM XP
CSA XP
FM/CSA XP
CSA GP
SIL (transmitter only)
Comments