Endress+Hauser T55
Explosion proof TC thermometer, US style

Endress+Hauser T55
Accuracy

Standard acc. to ASTM E-230
Special acc. to ASTM E-230

Response time

63% rt = 1 s

Max. process pressure (static)

not applicable

Operating temperature range

Type T:
-270 В°C ...370 В°C
(-454 В°F ...698 В°F)
Type J:
-210 В°C ...720 В°C
(-346 В°F ...1.328 В°F)
Type E:
-270 В°C ...820 В°C
(-454 В°F ...1.508 В°F)
Type K:
-270 В°C ...1.150 В°C
(-454 В°F ...2.102 В°F)
Type N:
-270 В°C ...1.150 В°C
(-454 В°F ...2.102 В°F)

Max. immersion length on request

up to 100" (2540 mm)
others on request

Item Number: T55
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry.

Measuring principle

Thermocouple

Characteristic / Application

Explosion Proof US style
modular temperature assembly
for heavy duty applications
with extension
to be used with existing thermowell

Thermowell / protection tube

to use with thermowell

Insert / probe

mineral insulated (MI), flexible

Outer diameter protection tube / Insert

1/4'' (6,35 mm)
3/8'' (9,53 mm)

Max. immersion length on request

up to 100" (2540 mm)
others on request

Material protection tube/ thermowell

Sensor sheath
316
Alloy 600

Optional coating

not applicable

Process connection

Thermowell connection
male thread:
NPT1/2"

Tip shape

straight

Surface roughness Ra

not applicable

Operating temperature range

Type T:
-270 В°C ...370 В°C
(-454 В°F ...698 В°F)
Type J:
-210 В°C ...720 В°C
(-346 В°F ...1.328 В°F)
Type E:
-270 В°C ...820 В°C
(-454 В°F ...1.508 В°F)
Type K:
-270 В°C ...1.150 В°C
(-454 В°F ...2.102 В°F)
Type N:
-270 В°C ...1.150 В°C
(-454 В°F ...2.102 В°F)

Max. process pressure (static)

not applicable

Accuracy

Standard acc. to ASTM E-230
Special acc. to ASTM E-230

Response time

63% rt = 1 s

Integration head transmitter

yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

FM XP
CSA XP
FM/CSA XP
CSA GP

Certification

SIL (transmitter only)

Comments

No comments yet

Write a comment