Endress+Hauser TLSC5
TC-Assembly S.A.Style
- Overview +
- Comments +
Thermocouple
Characteristic / ApplicationS.A. Style
universal range of application
usable with or without a thermowell
spring loaded for use in thermowell
Options available to construct removable inserts (spare parts)
to use with or without thermowell (can be ordered separately)
Insert / probemineral insulated (MI), flexible
Max. immersion length on requestup to 2.000 mm (78,74'')
Material protection tube/ thermowell1.4401 (316)
1.4841 (310)
Alloy 600 (2.4816)
Not defined
Process connectionUnion nipple:
NPT 1/2"
G1/2"
straight
Operating temperature rangeType J:
-210 ...760 В°C
(-346 ...1.400 В°F)
Type K:
-270 ...1.100 В°C
(-454 ...2.012 В°F)
Type N:
-270 ...1.100 В°C
(-454 ...2.012 В°F)
Type T:
-270 ...400 В°C
(-454 ...725 В°F)
at 20 В°C: 10 bar (150 psi) without thermowell
Accuracyclass 1 acc. to IEC 60584
Response timedepending on configuration
Integration head transmitteryes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
CertificationEN10204 3.1 Material traceability
Buy Endress+Hauser TLSC5 with the best possible price and delivery terms on eltra-trade.com