Endress+Hauser TH11
Modular RTD thermometer, US style

Endress+Hauser TH11
Accuracy

class A acc. to IEC 60751
class B acc. to IEC 60751

Response time

63% rt = 2,0 s

Max. process pressure (static)

at 20В°C: 250 bar (3.626 psi)
depends on configuration

Operating temperature range

PT 100:
-200 В°C ...600 В°C
-328 В°F ...1.112 В°F)

Max. immersion length on request

up to 96" (2439 mm)
others on request

Item Number: TH11
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Best in class temperature measurement technology for general applications.

Measuring principle

Resistance Temperature Detector

Characteristic / Application

US style
modular temperature assembly
threaded process connection
direct immersion style

Thermowell / protection tube

without (not intended to be used with thermowell)

Insert / probe

mineral insulated (MI), flexible
PTFE-insulated, rigid

Outer diameter protection tube / Insert

1/8'' (3,18 mm)
3/16''(4,76 mm)
1/4'' (6,35 mm)
3/8'' (9,53 mm)

Max. immersion length on request

up to 96" (2439 mm)
others on request

Material protection tube/ thermowell

Sensor sheath
316/316L

Process connection

male thread:
G1/2"
NPT1/2"
compression fitting:
NPT1/8"
NPT1/4"

Tip shape

straight
reduced

Surface roughness Ra

Not defined

Operating temperature range

PT 100:
-200 В°C ...600 В°C
-328 В°F ...1.112 В°F)

Max. process pressure (static)

at 20В°C: 250 bar (3.626 psi)
depends on configuration

Accuracy

class A acc. to IEC 60751
class B acc. to IEC 60751

Response time

63% rt = 2,0 s

Integration head transmitter

yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

transmitter only
FM IS
CSA IS
FM/CSA IS

Certification

SIL (transmitter only)

Comments

No comments yet

Write a comment