Endress+Hauser TSM470P U.S. Style Easytemp


Easytemp TSM470P,RTD-Transm.U.S.Style Temperature measuring device, compact. 3-A standard, surface finish: Ra min. 20 micro inch (240 grit).
- Overview
- Datasheet
- Alternative numbers
- Comments
Measuring principle
Resistance Temperature Detector
Characteristic / Application
US style
compact temperature probe
hygienic design
hygienic process connection
transmitter included (fixed range)
Thermowell / protection tube
without (not intended to use with thermowell)
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
5/32'' (3,97 mm)
Max. immersion length on request
up to 762 mm (30,00'')
Material protection tube/ thermowell
1.4435 (316L)
Process connection
hygienic:
clamp connections TRI-Clamp / Micro-Clamp
Tip shape
straight
Surface roughness Ra
0,5 Ојm (20 Ојin.)
Operating temperature range
PT 100:
-40 В°C ... 150 В°C
(-40 В°F ... 302 В°F)
Max. process pressure (static)
at 20 В°C: 100 bar (1.450 psi)
Accuracy
class A acc. to IEC 60751
Response time
63% rt = 2 s
Certification
3A
ASME BPE 2003
German Lloyd (GL) - marine approval
UL 3111-1
Comments