Endress+Hauser TH17
U.S. Style RTD-Assembly
- Overview +
- Comments +
Resistance Temperature Detector
Characteristic / ApplicationUS style
modular temperature assembly
hygienic design
hygienic process connection
with extension
without (not intended to be used with thermowell)
Insert / probemineral insulated (MI), flexible
PTFE-insulated, rigid
1/4'' (6,35 mm)
3/8'' (9,53 mm)
up to 4.877 mm (192,00'')
Material protection tube/ thermowell1.4404 (316L)
Process connectionhygienic:
clamp connections TRI-Clamp / Micro-Clamp
straight
reduced
0,8 Ојm (32 Ојin.)
Operating temperature rangePT 100:
-200 В°C ... 200 В°C
(-328 В°F ... 392 В°F)
at 20 В°C: 100 bar (1.450 psi)
Accuracyclass A acc. to IEC 60751
class 1/5 DIN
63% rt = 4 s
Integration head transmitteryes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsFM IS
CSA IS
FM/CSA IS
CSA
FDA
3A
SIL (transmitter only)