Endress+Hauser TH18
U.S. Style RTD-Assembly
- Overview +
- Comments +
Resistance Temperature Detector
Characteristic / ApplicationUS style
modular temperature assembly
hygienic design
hygienic process connection
without (not intended to use with thermowell)
Insert / probemineral insulated (MI), flexible
Outer diameter protection tube / Insert5/32'' (3,97 mm)
Max. immersion length on requestup to 4.877 mm (192,00'')
Material protection tube/ thermowell1.4404 (316L)
Process connectionhygienic:
clamp connections TRI-Clamp / Micro-Clamp
straight
Surface roughness Ra0,5 Ојm (20 Ојin.)
Operating temperature rangePT 100:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)
at 20 В°C: 100 bar (1.450 psi)
Accuracyclass A acc. to IEC 60751
Response time63% rt = 2,0 s
Integration head transmitteryes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsFM IS
CSA IS
FM/CSA IS
CSA
FDA
3A
ASME BPE 2003
SIL (transmitter only)
Buy Endress+Hauser TH18 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is your reliable source for industrial electrical parts. Our extensive product range includes various automation equipment, all available for fast delivery. We guarantee quality and competitive prices. Make us your preferred partner for all your electrical supply needs.