Festo CMMT-AS-C7-11A-P3-MP-S1
Servo drive
We ship to United States of America!
Festo CMMT-AS
Current, load supply | 9 A |
Nominal voltage AC | 400 V |
Phases of Nominal voltage | 3-phase |
Item Number:
CMMT-AS-C7-11A-P3-MP-S1
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Festo CMMT-AS Servo drive.
CMMT-AS-C7-11A-P3-MP-S1 Datasheet:
Type of mounting | Mounting plate, attached with screws |
Mounting position | Free convectionVertical |
Product weight | 4100 g |
Display | Green/yellow/red LED |
Operator controls | Optional: CDSB operator unit |
Conforms to standard | EN 61800-3EN 61800-5-1EN 61800-5-2EN ISO 13849-1 |
Based on standard | EN 50581EN 60204-1EN 61508-1EN 61508-2EN 61508-3EN 61508-4EN 61508-5EN 61508-6EN 61508-7EN 61800-2EN 62061 |
Approval | RCM trademarkGerman Technical Control Board (TГњV)c UL us listed (OL) |
KC mark | KC-EMV |
CE mark (see declaration of conformity) | To EU EMC DirectiveTo EC Machinery DirectiveIn accordance with EU RoHS Directive |
CE marking (see declaration of conformity) | To UK instructions for EMCTo UK regulations for machinesTo UK RoHS instructions |
Certificate issuing authority | German Technical Control Board (TГњV) Rheinland UK Ltd. 01/205U/5640.01/23German Technical Control Board (TГњV) Rheinland 01/205/5640.01/23UL E331130 |
Storage temperature | -25 °C ... 55 °C |
Ambient temperature | 0 °C ... 50 °C |
Note on ambient temperature | Power must be reduced by 3% per °C at ambient temperatures above 40°C. |
UL ambient temperature | 0 °C ... 40 °C |
Relative air humidity | 5 - 90%Non-condensing |
Max. installation height | 2000 m |
Note on max. installation height | From 1000 m: power reduction by 1% per 100 m. |
Degree of protection | IP20 |
Protection class | I |
Overvoltage category | III |
Pollution degree | 2 |
Immunity to surge | 6 kV |
Note on materials | RoHS-compliant |
LABS (PWIS) conformity | VDMA24364 zone III |
Phases of nominal operating voltage | 3-phase |
Nominal operating voltage AC | 400 V |
Permissible voltage fluctuations | +/- 10 % |
Input voltage range AC | 200 V ... 480 V |
Mains frequency | 48 Hz ... 62 Hz |
Nominal current, load supply | 9 A |
Peak current load power supply | 27 A |
Active PFC | no |
Mains filter | Integrated |
System voltage to EN 61800-5-1 | 300 V |
Max. short circuit current rating of the mains | 10 kA |
Mains types | TNIT |
Nominal voltage load voltage DC | 560 V |
Permissible range for load power supply | ± 10 % |
Max. intermediate circuit voltage DC | 800 V |
Brake resistor, integrated | 47 Ohm |
Pulse power, brake resistance | 13.6 kVA |
Pulse energy for braking resistor | 1200 Ws |
Nominal power braking resistor (IEC) | 100 W |
Brake resistor, external | 60 Ohm ... 85 Ohm |
Max. continuous output of the external braking resistor (IEC) | 1500 W |
Nominal voltage for logic power supply DC | 24 V |
Permissible range for logic voltage | ± 20 % |
Current consumption of logic power supply without clamping brake | 0.5 A |
Current consumption for logic supply with parking brake | 2 A |
Max. current consumption, logic power supply with clamping brake and I/O | 2.5 A |
Output voltage class AC | 3x (0 Ђ“ input) V |
Nominal current per phase, effective | 7 A |
Peak current per phase, effective | 21 A |
Max. peak current duration | 2 s |
Controller nominal output | 4000 VA |
Maximum output | 12000 VA |
Output frequency | 0 Hz ... 599 Hz |
Max. length of motor cable without external mains filter | 25 m |
Max. output current of holding brake | 1.5 A |
Max. voltage drop from logic supply to brake output | 1 V |
Number of inputs for motor temperature sensor | 1 |
Controller operating mode | Cascade controllerP position controllerPI speed controllerPI current regulator for F or MProfile operation with record and direct modeInterpolated mode via fieldbusSynchronised operating modesHomingSetting-upAutotuning |
Operating mode of drive unit | Field-oriented closed-loop controlPosition resolution 24 bit/revSampling rate 16 kHzPWM at 8 or 16 KHzVector modulation with 3rd harmonicReal-time data acquisition2x input capture (x, v, F)2x output trigger (x, v, F)2x position encoder input1x SYNC interface for encoder emulation or encoder input |
Ethernet interface, function | Parameterisation and commissioning |
Ethernet interface, protocol | TCP/IP |
Field bus, protocol | EtherCAT®EtherNet/IPModbus/TCPPROFINET IRTPROFINET RT |
Fieldbus interface, function | Bus connection incoming/outgoingEtherCAT® slavePROFINET slaveEtherNet/IP slave |
Fieldbus link | EtherCATEtherNet/IPModbus/TCPPROFINET |
Communication profile | CiA402CoE (CANopen over EtherCAT®)EoE (Ethernet over EtherCAT®)FoE (File over EtherCAT®)PROFIdriveDriveProfile |
Process interfacing | AC1: Adjustable-speed drivesAC3: Drives with positioning functionAC4: Synchronous servo applicationAdjustable-speed drivesDrives with positioning functionI/O mode for 256 positioning recordsInterpolated mode CSPInterpolated mode CSTInterpolated mode CSV |
Field bus interface, transmission rate | 100 Mbit/s |
Field bus, connection type | 2x socket |
Field bus, connection system | RJ45 |
Encoder interface, function | BiSS-CENDAT® 2.1 encoderEnDat® 2.2 encoderHiperface-GeberIncremental encoderNikonSIN/COS encoder |
Encoder interface 2, function | Incremental encoderSIN/COS encoder |
Synchronisation interface, function | Encoder emulation A/B/ZEncoder input A/B/Z |
Encoder interface output, features | 1 MHz maximum output frequencyMax. 16384 ppr |
Encoder interface input, features | 1 MHz maximum output frequencyMax. 16384 ppr |
Number of digital logic inputs | 12 |
Switching logic for inputs | PNP (positive switching) |
Features of logic input | Freely configurable in some casesSafety inputs in some casesNot galvanically isolated |
Specification logic input | Based on IEC 61131-2, type 3 |
Working range of logic input | -3 V ... 30 V |
Number of high-speed logic inputs | 2 |
Time resolution of high-speed logic inputs | 1 µs |
Number of digital logic outputs 24 V DC | 6 |
Switching logic for outputs | PNP (positive switching) |
Features of digital logic outputs | Freely configurable in some casesNot galvanically isolatedDiagnostics outputs in some cases |
Max. current digital logic outputs | 20 mA |
Number of high-speed switching outputs | 2 |
Time resolution of high-speed switching outputs | 1 µs |
Number of floating switching outputs | 1 |
Max. current of the floating switching outputs | 50 mA |
Number of analogue setpoint inputs | 1 |
Features of setpoint inputs | Differential inputsConfigurable for speedConfigurable for current/force |
Working range setpoint input | ± 10 V |
Working range of analogue inputs | ± 10 V |
Impedance of setpoint input | 70 kOhm |
Safety function | Safe brake control (SBC)Safe torque off (STO)Safe Stop 1 (SS1) |
Safety Integrity Level (SIL) | Safe brake control (SBC)/SIL 3/SILCL 3Safe torque off (STO)/SIL 3/SILCL 3 |
Performance Level (PL) | Safe brake control (SBC)/category 3, performance level eSafe Torque Off (STO)/category 4, performance level e |
Diagnostic coverage | 97 % |
SFF Safe Failure Fraction | 99 % |
Hardware fault tolerance | 1 |
Number of safe 2-pin inputs | 2 |
Number of diagnostic outputs | 2 |
Buy Festo CMMT-AS-C7-11A-P3-MP-S1 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is a trusted industrial automation supplier. We offer a vast selection of products from renowned manufacturers. Worldwide delivery is available, ensuring you receive your order promptly. Competitive prices and exceptional service are our priorities. Experience the benefits of partnering with us for your automation needs.
People also buy
Comments