Festo CPX-E-CEC-C1-PN
Remote I/O and network interface component
We ship to United States of America!
Festo CPX-E
Item Number:
CPX-E-CEC-C1-PN
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Festo CPX-E Remote I/O and network interface component.
CPX-E-CEC-C1-PN Datasheet:
Dimensions (W x L x H) | 75.9 mm x 82.5 mm x 124.3 mm |
Grid dimension | 18.9 mm |
Type of mounting | With H-rail |
Max. number of modules | 10 |
Product weight | 288 g |
Mounting position | VerticalHorizontal |
Ambient temperature | -5 °C ... 50 °C |
Note on ambient temperature | -5 - 60°C for vertical installation |
Storage temperature | -20 °C ... 70 °C |
Relative air humidity | 95 %Non-condensing |
Degree of protection | IP20 |
Corrosion resistance class CRC | 0 - No corrosion stress |
Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 |
Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
Protection against direct and indirect contact | PELV |
LABS (PWIS) conformity | VDMA24364 zone III |
CE mark (see declaration of conformity) | To EU EMC DirectiveIn accordance with EU RoHS Directive |
CE marking (see declaration of conformity) | To UK instructions for EMCTo UK RoHS instructions |
KC mark | KC-EMV |
Approval | RCM trademarkc UL us listed (OL) |
Certificate issuing authority | UL E239998 |
Note on materials | RoHS-compliant |
Material housing | PA |
Diagnostics via LED | Force modeModule statusNetwork faultNetwork status, engineering port 1Network status, engineering port 2EtherCAT® network statusNetwork status, port 1Network status, port 2RunPower supply, electronics/sensorsLoad power supplySystem faultService required |
Operator controls | DIL switch for RUN/STOPOptional: CDSB operator unit |
IP address setting | DHCPVia CODESYSOptional: via operator unit CDSB |
Fieldbus interface | Ethernet |
Field bus, protocol | LLDPMRP, MRPD (ring redundancy)PROFINET I&M0 .. 3PROFINET IOPROFINET RTPROFINET shared deviceSNMP |
Fieldbus interface, function | Bus connection incoming/outgoing |
Field bus, connection type | 2x socket |
Field bus, connection system | RJ45 |
Fieldbus interface, connection pattern | 00995789 |
Field bus, connection pattern | 8 |
Field bus interface, electrical isolation | yes |
Field bus interface, transmission rate | 100 Mbit/s |
Fieldbus interface 2, type | Ethernet |
Fieldbus interface 2, protocol | CoEEoEEtherCAT®EtherCAT masterFoE |
Fieldbus interface 2, function | Outgoing bus connection |
Fieldbus interface 2, connection type | Socket |
Fieldbus interface 2, connection technology | RJ45 |
Fieldbus interface 2, connection pattern | 00995789 |
Fieldbus interface 2, number of pins/wires | 8 |
Fieldbus interface 2, galvanic isolation | yes |
Fieldbus interface 2, transmission rate | 100 Mbit/s |
Ethernet interface, connection type | 2x socket |
Ethernet interface, protocol | EasyIPModbus® TCPOPC UATCP/IP |
Ethernet interface, function | DiagnosticsSwitch |
Ethernet interface, connection system | RJ45 |
Ethernet interface, connection pattern | 00995789 |
Ethernet interface, number of pins/wires | 8 |
Ethernet interface, transmission rate | 10 Mbit/s100 Mbit/s |
Max. address volume, inputs | 64 Byte |
Fieldbus interface, max. address volume for inputs | 512 Byte |
Max. address volume, outputs | 64 Byte |
Fieldbus interface, max. address volume for outputs | 512 Byte |
System parameters | Diagnostic memoryFail-safe responseSystem start |
Module parameters | Channel alarms bundlingUndervoltage diagnosticsChannel alarms for undervoltageProcess value representation of analogue modules |
Configuration support | Control unit CDSBCODESYS V3GSDML file |
Additional functions | CODESYS V3 |
CPU data | 512 MB RAMDual Core 766 MHz |
storage medium | Micro SD <= 32 GBUSB memory stick <= 32 GB |
Power supply, function | Electronics and sensors |
Power supply, connection type | Terminal strip |
Power supply, note on connection type | > 4 A and UL 2x terminal strip for power supply |
power supply, connection system | Spring-loaded terminal |
Power supply, connection pattern | 00995847 |
Power supply, number of pins/wires | 4 |
Nominal DC operating voltage, electronics/sensors | 24 V |
Permissible voltage fluctuations for electronics/sensors | ± 25% |
Power supply, conductor diameter | 0.2 mmІ ... 1.5 mmІ |
Power supply, note on conductor diameter | 0.2 - 2.5 mmІ for flexible conductors without wire end sleeves |
Max. power supply | 8 A |
Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 150 mA |
Power failure bridging | 20 ms |
Reverse polarity protection | 24 V sensor supply against 0 V sensor supply |
USB-interface | USB 2.0 |
Programming software | CODESYS provided by Festo |
Program memory | 100 MB user program |
Processing time | Approx. 200 µs/1 k instruction |
Function modules | And othersRead CPX-E module diagnosticsCPX-E diagnostic statusCopy CPX-E diagnostic trace |
Buffering time real-time clock | 3 Weeks |
Flag | 120 kB retentive dataCODESYS variable concept |
Buy Festo CPX-E-CEC-C1-PN with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is a global leader in industrial automation supply. Our extensive catalog includes top brands, with worldwide delivery and competitive pricing. We focus on customer satisfaction and reliability. Experience our exceptional service and support for your automation needs.
People also buy
Comments
No comments yet