Festo CPX-E-CEC-M1-PN
Remote I/O and network interface component

Festo CPX-E-CEC-M1-PN
We ship to United States of America!

Festo CPX-E

Item Number: CPX-E-CEC-M1-PN
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +

Festo CPX-E Remote I/O and network interface component.

CPX-E-CEC-M1-PN Datasheet:

Dimensions (W x L x H)75.9 mm x 82.5 mm x 124.3 mm
Grid dimension18.9 mm
Type of mountingWith H-rail
Max. number of modules10
Product weight288 g
Mounting positionVerticalHorizontal
Ambient temperature-5 °C ... 50 °C
Note on ambient temperature-5 - 60°C for vertical installation
Storage temperature-20 °C ... 70 °C
Relative air humidity95 %Non-condensing
Degree of protectionIP20
Corrosion resistance class CRC0 - No corrosion stress
Vibration resistanceTransport application test with severity level 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Protection against direct and indirect contactPELV
LABS (PWIS) conformityVDMA24364 zone III
CE mark (see declaration of conformity)To EU EMC DirectiveIn accordance with EU RoHS Directive
CE marking (see declaration of conformity)To UK instructions for EMCTo UK RoHS instructions
KC markKC-EMV
ApprovalRCM trademarkc UL us listed (OL)
Certificate issuing authorityUL E239998
Note on materialsRoHS-compliant
Material housingPA
Diagnostics via LEDForce modeModule statusNetwork faultNetwork status, engineering port 1Network status, engineering port 2EtherCAT® network statusNetwork status, port 1Network status, port 2RunPower supply, electronics/sensorsLoad power supplySystem faultService required
Operator controlsDIL switch for RUN/STOPOptional: CDSB operator unit
IP address settingDHCPVia CODESYSOptional: via operator unit CDSB
Fieldbus interfaceEthernet
Field bus, protocolLLDPMRP, MRPD (ring redundancy)PROFINET I&M0 .. 3PROFINET IOPROFINET RTPROFINET shared deviceSNMP
Fieldbus interface, functionBus connection incoming/outgoing
Field bus, connection type2x socket
Field bus, connection systemRJ45
Fieldbus interface, connection pattern00995789
Field bus, connection pattern8
Field bus interface, electrical isolationyes
Field bus interface, transmission rate100 Mbit/s
Fieldbus interface 2, typeEthernet
Fieldbus interface 2, protocolCoEEoEEtherCAT®EtherCAT masterFoE
Fieldbus interface 2, functionOutgoing bus connection
Fieldbus interface 2, connection typeSocket
Fieldbus interface 2, connection technologyRJ45
Fieldbus interface 2, connection pattern00995789
Fieldbus interface 2, number of pins/wires8
Fieldbus interface 2, galvanic isolationyes
Fieldbus interface 2, transmission rate100 Mbit/s
Ethernet interface, connection type2x socket
Ethernet interface, protocolEasyIPModbus® TCPOPC UATCP/IP
Ethernet interface, functionDiagnosticsSwitch
Ethernet interface, connection systemRJ45
Ethernet interface, connection pattern00995789
Ethernet interface, number of pins/wires8
Ethernet interface, transmission rate10 Mbit/s100 Mbit/s
Max. address volume, inputs64 Byte
Fieldbus interface, max. address volume for inputs512 Byte
Max. address volume, outputs64 Byte
Fieldbus interface, max. address volume for outputs512 Byte
System parametersDiagnostic memoryFail-safe responseSystem start
Module parametersChannel alarms bundlingUndervoltage diagnosticsChannel alarms for undervoltageProcess value representation of analogue modules
Configuration supportControl unit CDSBCODESYS V3GSDML file
Additional functionsCoDeSys V3 with SoftMotion
CPU data512 MB RAMDual Core 766 MHz
storage mediumMicro SD <= 32 GBUSB memory stick <= 32 GB
Power supply, functionElectronics and sensors
Power supply, connection typeTerminal strip
Power supply, note on connection type> 4 A and UL 2x terminal strip for power supply
power supply, connection systemSpring-loaded terminal
Power supply, connection pattern00995847
Power supply, number of pins/wires4
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25%
Power supply, conductor diameter0.2 mmІ ... 1.5 mmІ
Power supply, note on conductor diameter0.2 - 2.5 mmІ for flexible conductors without wire end sleeves
Max. power supply8 A
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 150 mA
Power failure bridging20 ms
Reverse polarity protection24 V sensor supply against 0 V sensor supply
USB-interfaceUSB 2.0
Programming softwareCODESYS provided by Festo
Program memory100 MB user program
Processing timeApprox. 200 µs/1 k instruction
Function modulesAnd othersRead CPX-E module diagnosticsCPX-E diagnostic statusCopy CPX-E diagnostic trace
Buffering time real-time clock3 Weeks
Flag120 kB retentive dataCODESYS variable concept

Buy Festo CPX-E-CEC-M1-PN with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. offers premium industrial control products. Our vast inventory and express delivery options ensure you receive your order quickly. We prioritize quality and customer satisfaction. Contact us today to learn more about our offerings.

Comments

No comments yet

Write a comment