CPX-E-CEC-M1-PN Datasheet:
Dimensions (W x L x H) | 75.9 mm x 82.5 mm x 124.3 mm |
Grid dimension | 18.9 mm |
Type of mounting | With H-rail |
Max. number of modules | 10 |
Product weight | 288 g |
Mounting position | VerticalHorizontal |
Ambient temperature | -5 °C ... 50 °C |
Note on ambient temperature | -5 - 60°C for vertical installation |
Storage temperature | -20 °C ... 70 °C |
Relative air humidity | 95 %Non-condensing |
Degree of protection | IP20 |
Corrosion resistance class CRC | 0 - No corrosion stress |
Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 |
Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
Protection against direct and indirect contact | PELV |
LABS (PWIS) conformity | VDMA24364 zone III |
CE mark (see declaration of conformity) | To EU EMC DirectiveIn accordance with EU RoHS Directive |
CE marking (see declaration of conformity) | To UK instructions for EMCTo UK RoHS instructions |
KC mark | KC-EMV |
Approval | RCM trademarkc UL us listed (OL) |
Certificate issuing authority | UL E239998 |
Note on materials | RoHS-compliant |
Material housing | PA |
Diagnostics via LED | Force modeModule statusNetwork faultNetwork status, engineering port 1Network status, engineering port 2EtherCAT® network statusNetwork status, port 1Network status, port 2RunPower supply, electronics/sensorsLoad power supplySystem faultService required |
Operator controls | DIL switch for RUN/STOPOptional: CDSB operator unit |
IP address setting | DHCPVia CODESYSOptional: via operator unit CDSB |
Fieldbus interface | Ethernet |
Field bus, protocol | LLDPMRP, MRPD (ring redundancy)PROFINET I&M0 .. 3PROFINET IOPROFINET RTPROFINET shared deviceSNMP |
Fieldbus interface, function | Bus connection incoming/outgoing |
Field bus, connection type | 2x socket |
Field bus, connection system | RJ45 |
Fieldbus interface, connection pattern | 00995789 |
Field bus, connection pattern | 8 |
Field bus interface, electrical isolation | yes |
Field bus interface, transmission rate | 100 Mbit/s |
Fieldbus interface 2, type | Ethernet |
Fieldbus interface 2, protocol | CoEEoEEtherCAT®EtherCAT masterFoE |
Fieldbus interface 2, function | Outgoing bus connection |
Fieldbus interface 2, connection type | Socket |
Fieldbus interface 2, connection technology | RJ45 |
Fieldbus interface 2, connection pattern | 00995789 |
Fieldbus interface 2, number of pins/wires | 8 |
Fieldbus interface 2, galvanic isolation | yes |
Fieldbus interface 2, transmission rate | 100 Mbit/s |
Ethernet interface, connection type | 2x socket |
Ethernet interface, protocol | EasyIPModbus® TCPOPC UATCP/IP |
Ethernet interface, function | DiagnosticsSwitch |
Ethernet interface, connection system | RJ45 |
Ethernet interface, connection pattern | 00995789 |
Ethernet interface, number of pins/wires | 8 |
Ethernet interface, transmission rate | 10 Mbit/s100 Mbit/s |
Max. address volume, inputs | 64 Byte |
Fieldbus interface, max. address volume for inputs | 512 Byte |
Max. address volume, outputs | 64 Byte |
Fieldbus interface, max. address volume for outputs | 512 Byte |
System parameters | Diagnostic memoryFail-safe responseSystem start |
Module parameters | Channel alarms bundlingUndervoltage diagnosticsChannel alarms for undervoltageProcess value representation of analogue modules |
Configuration support | Control unit CDSBCODESYS V3GSDML file |
Additional functions | CoDeSys V3 with SoftMotion |
CPU data | 512 MB RAMDual Core 766 MHz |
storage medium | Micro SD <= 32 GBUSB memory stick <= 32 GB |
Power supply, function | Electronics and sensors |
Power supply, connection type | Terminal strip |
Power supply, note on connection type | > 4 A and UL 2x terminal strip for power supply |
power supply, connection system | Spring-loaded terminal |
Power supply, connection pattern | 00995847 |
Power supply, number of pins/wires | 4 |
Nominal DC operating voltage, electronics/sensors | 24 V |
Permissible voltage fluctuations for electronics/sensors | ± 25% |
Power supply, conductor diameter | 0.2 mmІ ... 1.5 mmІ |
Power supply, note on conductor diameter | 0.2 - 2.5 mmІ for flexible conductors without wire end sleeves |
Max. power supply | 8 A |
Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 150 mA |
Power failure bridging | 20 ms |
Reverse polarity protection | 24 V sensor supply against 0 V sensor supply |
USB-interface | USB 2.0 |
Programming software | CODESYS provided by Festo |
Program memory | 100 MB user program |
Processing time | Approx. 200 µs/1 k instruction |
Function modules | And othersRead CPX-E module diagnosticsCPX-E diagnostic statusCopy CPX-E diagnostic trace |
Buffering time real-time clock | 3 Weeks |
Flag | 120 kB retentive dataCODESYS variable concept |