Festo VSNC
Solenoid valve

Festo VSNC
We ship to United States of America!
Item Number: VSNC
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview +
  • Comments +

Festo Solenoid valve.

VSNC Datasheet:

Valve function5/2 double solenoid5/2-way or 3/2-way, convertible5/3-way, pressurised5/3 exhausted5/3 closed
Type of actuationElectric
Construction width32 mm
Standard nominal flow rate (standardised to DIN 1343)800 l/min ... 1350 l/min
pneumatic working portNAMUR port pattern
Operating voltage110V AC120V AC12V DC230V AC240V AC24V AC24V DC48V AC48V DCVia solenoid coil, must be ordered separately
Operating pressure0.15 MPa ... 1 MPa
Operating pressure1.5 bar ... 10 bar
DesignPiston gate valvePoppet seat
Type of resetMechanical spring
Approvalc UL us - Recognized (OL)
CE mark (see declaration of conformity)To EU Explosion Protection Directive (ATEX)To EU Low Voltage Directive
Explosion protection certification outside the EUClass I, Div. 1 (US)Class I, Div. 2 (US)Class II, Div. 1 (US)Class II, Div. 2 (US)Class III, Div. 1 (US)Class III, Div. 2 (US)EPL Da (IECEx)EPL Db (IEC-EX)EPL Db (KR)EPL Dc (KR)EPL Ga (IEC-EX)EPL Ga (KR)EPL Gb (IECEx)EPL Gb (KR)EPL Gc (KR)
Certificate issuing authorityDNVGL-TAA000011J
ATEX category gasII 2GII 3G
ATEX category dustII 2DII 3D
Explosion ignition protection type for gasAEx m II T4Ex db IIC T4 GbEx db IIC T5 GbEx ia IIC T6 GaEx ia IIC T6...T5 GaEx mb IIC T6Ex nA IIC T5 X Gc
Explosion ignition protection type for dustEx ia IIIB T135°C DaEx mb tb IIIC T80°CEx t IIIC T80°C DbEx tb IIIC T100°C DbEx tb IIIC T135°C DbEx tc IIIC T95°C X Dc
Explosion ambient temperature-20°C <= Ta <= +50°C-20°C <= Ta <= +60°C-40°C <= Ta <= +50°C-40°C <= Ta <= +65°C-65°C <= Ta <= +40°C-65°C <= Ta <= +55°C
Degree of protectionIP65IP66IP67With plug socketTo IEC 60529
Exhaust-air functionWith flow control option
Sealing principleSoft
Mounting positionoptional
Conforms to standardVDI/VDE 3845 (NAMUR)
Manual overrideDetentingNoneNon-detentingCovered
Type of pilotingPilot actuated
Pilot air supplyInternal
Flow directionNon-reversible
Symbol00991005009910180099102100991080009910820099108300991728009918310099195300995701
lapOverlapUnderlap
Signal status displayWith accessories
b value0.4 ... 0.5
C value2.1 l/sbar ... 5.6 l/sbar
Standard nominal flow rate, exhaust return 4->3110 l/min
Switching time off6 ms ... 120 ms
Switching time on4 ms ... 35 ms
Switching time reversal2 ms ... 55 ms
Duty cycle100%
Characteristic coil data110/120 V AC: 50/60 Hz, pick-up power 2.7 VA, holding power 1.9 VA110/120 V AC: 50/60 Hz, pick-up power 4.4 VA, holding power 3.3 VA110/120 V AC: 50/60 Hz, pick-up power 5.2 VA, holding power 3.1 VA110/120 V AC: 50/60 Hz, pick-up power 6.9 VA, holding power 3.1 VA110 V AC: 50/60 Hz, pick-up power 7.7 VA, holding power 3.8 VA120 V AC: 60 Hz, pick-up power 10.0 VA, holding power 6.8 VA12 V DC: 2.8 W12 V DC: 3.4 W230/240 V AC: 50/60 Hz, pick-up power 3.9 VA, holding power 2.8 VA230/240 V AC: 50/60 Hz, pick-up power 5.8 VA, holding power 4.6 VA230 V AC: 50/60 Hz, pick-up power 10.0 VA, holding power 6.0 VA230 V AC: 50/60 Hz, pick-up power 11.5 VA, holding power 8.0 VA230 V AC: 50/60 Hz, pick-up power 6.2 VA, holding power 3.7 VA230 V AC: 50/60 Hz, pick-up power 6.9 VA, holding power 4.1 VA24 V DC: 0.8 W24 V DC: 2.1 W24 V DC: 2.7 W24 V DC: 3.3 W24 V DC: 4.6 W24 V AC: 50/60 Hz, pick-up power 2.5 VA, holding power 1.7 VA24 V AC: 50/60 Hz, pick-up power 3.9 VA, holding power 2.6 VA24 V DC: 0.7 W24 V DC: 1.2 W24 V DC: 2.6 W48 V AC: 50/60 Hz, pick-up power 2.5 VA, holding power 1.7 VA48 V AC: 50/60 Hz, pick-up power 3.9 VA, holding power 2.7 VA48 V DC: 2.8 W48 V DC: 3.4 WSee solenoid coil, to be ordered separately
Permissible voltage fluctuations+/- 10 %
Explosion protectionClass I, Div. 1 (US)Class I, Div. 2 (US)Class II, Div. 1 (US)Class II, Div. 2 (US)Class III, Div. 1 (US)Class III, Div. 2 (US)The information in the certificate must be observed!Zone 0 (IEC-EX)Zone 0 (KR)Zone 1 (ATEX)Zone 1 (IEC-EX)Zone 1 (KR)Zone 2 (ATEX)Zone 2 (KR)Zone 20 (IEC-EX)Zone 21 (ATEX)Zone 21 (IEC-EX)Zone 21 (KR)Zone 22 (ATEX)Zone 22 (KR)
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B2-LVDMA24364 zone III
Media temperature-20 °C ... 60 °C
Ambient temperature-20 °C ... 60 °C
Product weight335 g ... 685 g
Electrical connection3-pinType AType BCable connector M20x1.5M12x1, A-coded to EN 61076-2-101PlugsTo EN 175301-803To industry standard (11 mm)
Type of mountingWith through-hole
Breather connectionNot ducted
Pneumatic connection, port 1G1/41/4 NPTQS-6QS-8QS-10QS-1/4QS-5/16QS-3/8
Pneumatic connection, port 2NAMUR port pattern
Pneumatic connection, port 3G1/41/4 NPTQS-6QS-8QS-10QS-1/4QS-5/16QS-3/8
Pneumatic connection, port 4NAMUR port pattern
Pneumatic connection, port 5G1/41/4 NPTQS-6QS-8QS-10QS-5/16QS-1/4QS-3/8
Note on materialsRoHS-compliant
Material sealsNBR
Material housingWrought aluminium alloy
Material screwsGalvanised steel

Buy Festo VSNC with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is an online electrical store. Our product range includes industrial sensors, motor control components, pneumatic automation, and many other automation equipment. You can receive your order in any country in the world. By providing you with minimum prices, you can save money. You don't need to pay in advance if you are our regular customer. We respect your needs and are interested in their total satisfaction.