Festo VSNC
Solenoid valve
We ship to United States of America!
Item Number:
VSNC
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Festo Solenoid valve.
VSNC Datasheet:
Valve function | 5/2 double solenoid5/2-way or 3/2-way, convertible5/3-way, pressurised5/3 exhausted5/3 closed |
Type of actuation | Electric |
Construction width | 32 mm |
Standard nominal flow rate (standardised to DIN 1343) | 800 l/min ... 1350 l/min |
pneumatic working port | NAMUR port pattern |
Operating voltage | 110V AC120V AC12V DC230V AC240V AC24V AC24V DC48V AC48V DCVia solenoid coil, must be ordered separately |
Operating pressure | 0.15 MPa ... 1 MPa |
Operating pressure | 1.5 bar ... 10 bar |
Design | Piston gate valvePoppet seat |
Type of reset | Mechanical spring |
Approval | c UL us - Recognized (OL) |
CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX)To EU Low Voltage Directive |
Explosion protection certification outside the EU | Class I, Div. 1 (US)Class I, Div. 2 (US)Class II, Div. 1 (US)Class II, Div. 2 (US)Class III, Div. 1 (US)Class III, Div. 2 (US)EPL Da (IECEx)EPL Db (IEC-EX)EPL Db (KR)EPL Dc (KR)EPL Ga (IEC-EX)EPL Ga (KR)EPL Gb (IECEx)EPL Gb (KR)EPL Gc (KR) |
Certificate issuing authority | DNVGL-TAA000011J |
ATEX category gas | II 2GII 3G |
ATEX category dust | II 2DII 3D |
Explosion ignition protection type for gas | AEx m II T4Ex db IIC T4 GbEx db IIC T5 GbEx ia IIC T6 GaEx ia IIC T6...T5 GaEx mb IIC T6Ex nA IIC T5 X Gc |
Explosion ignition protection type for dust | Ex ia IIIB T135°C DaEx mb tb IIIC T80°CEx t IIIC T80°C DbEx tb IIIC T100°C DbEx tb IIIC T135°C DbEx tc IIIC T95°C X Dc |
Explosion ambient temperature | -20°C <= Ta <= +50°C-20°C <= Ta <= +60°C-40°C <= Ta <= +50°C-40°C <= Ta <= +65°C-65°C <= Ta <= +40°C-65°C <= Ta <= +55°C |
Degree of protection | IP65IP66IP67With plug socketTo IEC 60529 |
Exhaust-air function | With flow control option |
Sealing principle | Soft |
Mounting position | optional |
Conforms to standard | VDI/VDE 3845 (NAMUR) |
Manual override | DetentingNoneNon-detentingCovered |
Type of piloting | Pilot actuated |
Pilot air supply | Internal |
Flow direction | Non-reversible |
Symbol | 00991005009910180099102100991080009910820099108300991728009918310099195300995701 |
lap | OverlapUnderlap |
Signal status display | With accessories |
b value | 0.4 ... 0.5 |
C value | 2.1 l/sbar ... 5.6 l/sbar |
Standard nominal flow rate, exhaust return 4->3 | 110 l/min |
Switching time off | 6 ms ... 120 ms |
Switching time on | 4 ms ... 35 ms |
Switching time reversal | 2 ms ... 55 ms |
Duty cycle | 100% |
Characteristic coil data | 110/120 V AC: 50/60 Hz, pick-up power 2.7 VA, holding power 1.9 VA110/120 V AC: 50/60 Hz, pick-up power 4.4 VA, holding power 3.3 VA110/120 V AC: 50/60 Hz, pick-up power 5.2 VA, holding power 3.1 VA110/120 V AC: 50/60 Hz, pick-up power 6.9 VA, holding power 3.1 VA110 V AC: 50/60 Hz, pick-up power 7.7 VA, holding power 3.8 VA120 V AC: 60 Hz, pick-up power 10.0 VA, holding power 6.8 VA12 V DC: 2.8 W12 V DC: 3.4 W230/240 V AC: 50/60 Hz, pick-up power 3.9 VA, holding power 2.8 VA230/240 V AC: 50/60 Hz, pick-up power 5.8 VA, holding power 4.6 VA230 V AC: 50/60 Hz, pick-up power 10.0 VA, holding power 6.0 VA230 V AC: 50/60 Hz, pick-up power 11.5 VA, holding power 8.0 VA230 V AC: 50/60 Hz, pick-up power 6.2 VA, holding power 3.7 VA230 V AC: 50/60 Hz, pick-up power 6.9 VA, holding power 4.1 VA24 V DC: 0.8 W24 V DC: 2.1 W24 V DC: 2.7 W24 V DC: 3.3 W24 V DC: 4.6 W24 V AC: 50/60 Hz, pick-up power 2.5 VA, holding power 1.7 VA24 V AC: 50/60 Hz, pick-up power 3.9 VA, holding power 2.6 VA24 V DC: 0.7 W24 V DC: 1.2 W24 V DC: 2.6 W48 V AC: 50/60 Hz, pick-up power 2.5 VA, holding power 1.7 VA48 V AC: 50/60 Hz, pick-up power 3.9 VA, holding power 2.7 VA48 V DC: 2.8 W48 V DC: 3.4 WSee solenoid coil, to be ordered separately |
Permissible voltage fluctuations | +/- 10 % |
Explosion protection | Class I, Div. 1 (US)Class I, Div. 2 (US)Class II, Div. 1 (US)Class II, Div. 2 (US)Class III, Div. 1 (US)Class III, Div. 2 (US)The information in the certificate must be observed!Zone 0 (IEC-EX)Zone 0 (KR)Zone 1 (ATEX)Zone 1 (IEC-EX)Zone 1 (KR)Zone 2 (ATEX)Zone 2 (KR)Zone 20 (IEC-EX)Zone 21 (ATEX)Zone 21 (IEC-EX)Zone 21 (KR)Zone 22 (ATEX)Zone 22 (KR) |
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) |
Corrosion resistance class CRC | 2 - Moderate corrosion stress |
LABS (PWIS) conformity | VDMA24364-B2-LVDMA24364 zone III |
Media temperature | -20 °C ... 60 °C |
Ambient temperature | -20 °C ... 60 °C |
Product weight | 335 g ... 685 g |
Electrical connection | 3-pinType AType BCable connector M20x1.5M12x1, A-coded to EN 61076-2-101PlugsTo EN 175301-803To industry standard (11 mm) |
Type of mounting | With through-hole |
Breather connection | Not ducted |
Pneumatic connection, port 1 | G1/41/4 NPTQS-6QS-8QS-10QS-1/4QS-5/16QS-3/8 |
Pneumatic connection, port 2 | NAMUR port pattern |
Pneumatic connection, port 3 | G1/41/4 NPTQS-6QS-8QS-10QS-1/4QS-5/16QS-3/8 |
Pneumatic connection, port 4 | NAMUR port pattern |
Pneumatic connection, port 5 | G1/41/4 NPTQS-6QS-8QS-10QS-5/16QS-1/4QS-3/8 |
Note on materials | RoHS-compliant |
Material seals | NBR |
Material housing | Wrought aluminium alloy |
Material screws | Galvanised steel |
Buy Festo VSNC with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is an online electrical store. Our product range includes industrial sensors, motor control components, pneumatic automation, and many other automation equipment. You can receive your order in any country in the world. By providing you with minimum prices, you can save money. You don't need to pay in advance if you are our regular customer. We respect your needs and are interested in their total satisfaction.
People also buy
Comments
No comments yet