Pepperl+Fuchs 6000 Control System
Type X and Ex px purge and pressurization system
- Certified for Class I, Class II, Division I- Zone 1 / Zone 21 to nonhazardous
- Intrinsically safe electrical/pneumatic manifold assembly
- Intrinsically safe user interface for programming and monitoring the system
- Enclosure volume up to 450 ft3 (12.1 m3)
- Control Unit monitors system operation and controls enclosure power
- Universal mounting (brackets included)
- 316L stainless steel Type 4X enclosure
- Overview
- Comments
Material | Enclosure: 316L (UNS S31603) stainless steel Manifold valve: anodized 6082 aluminum Fittings: 316L (UNS S31603) stainless steel |
Input II | Temperature inputs |
Rated voltage | 90 ... 264 V AC, 48 ... 62 Hz / 0.2 A 20 ... 30 V DC |
Dimensions | 183 x 367.5 x 152.5 mm (7.20 x 14.45 x 6.00 inch) |
Connection | Terminal blocks |
Input I | Inputs 1, 2, 3, 4: contact input, 5 VDC @ 2 mA |
Output I | AUX 1 |
Connection type | Pneumatic : Inlet fitting to manifold: 3/8"" NPT (female) Outlet fitting from manifold: 3/8"" bulkhead fitting (provided) |
Storage temperature | -30 ... 80 В°C (-22 ... 176 В°F) |
Mass | -WH- 11.4 kg (25 lb) -CK- 7.2 kg (16 lb) |
Pressure requirement | 20 ... 120 psig (1.4 ... 8.3 bar) (138 ... 827 kPa) regulated |
Operating mode | manual, semi-automatic, or fully automatic - programmable |
Relative humidity | 5 ... 95 %, noncondensing |
Output III | ENC_1, ENC_2 (protected enclosure contacts) |
Degree of protection | Type 4X , IP66 |
Number of volume exchanges | 4 to 19 |
Cable gland | 4 - M16 x 1.5 cable gland |
Safe pressure | Gas: 0.25"" wc (6.4 mm wc) (0.625 mbar) (62 Pa) Dust: 0.65"" wc (16.5 mm wc) (1.6 mbar) (162 Pa) Gas and Dust: 0.65"" wc (16.5 mm wc) (1.6 mbar) ( 162 Pa) |
Output II | AUX 2 |
IECEx approval | 6000 Main Control unit with housing 6000-xx-S2-UN-xx-xx: IECEx UL 08.0003X Ex db [ib pxb] IIC T4 Gb (-20 В°C Ta 60 В°C) Ex db tb [ib pxb] IIIC T60 В°C Db (-20 В°C Ta 50 В°C) |
Input III | EPV-6000 Vent |
LED indicator | Safe pressure: Blue - safe pressure is achieved Enclosure power: Green - power on; Red - power off Rapid exchange: Blue - purging is running System bypass: Yellow - bypass is activated Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - 6000 series system fault |
Impact resistance | 30 g, 11 ms, all axes |
Flow rate for leakage compensation | Depends on enclosure seal. With EPV-6000-xx-01, EPV-6000-xx-02 0.35 SCFM @ 0.25"" wc (10.0 l/min @ 6.3 mbar) 1.0 SCFM @ 0.75"" wc (28.0 l/min @ 1.9 mbar) With EPV-6000-xx-03, EPV-6000-xx-04 0.22 SCFM @ 0.25"" wc (6.2 l/min @ 6.3 mbar) 0.58 SCFM @ 0.75"" wc (16.4 l/min @ 1.9 mbar) With EPV-6000-xx-05, EPV-6000-xx-06 0.15 SCFM @ 0.25"" wc (4.2 l/min @ 6.3 mbar) 0.35 SCFM @ 0.75"" wc (10.0 l/min @ 1.9 mbar) |
UL approval | 6000 Main control unit with housing 6000-xx-S2-UN-xx-xx: cULus Class I, Division 1, Groups A,B,C,D T4 (-20 В°C Ta 60 В°C) Class II, Division 1, Groups E,F,G T4 (-20 В°C Ta 50 В°C) Class I, Zone 1, Group IIC T4 (-20 В°C Ta 60 В°C) Class II, Zone 21, Group IIIC T60 В°C (-20 В°C Ta 50 В°C) [Ex i] Associated Equipment Ex db [ib pxb] IIC T4 (-20 В°C Ta 60 В°C) Ex db tb [ib pxb] IIIC T4 (-20 В°C Ta 50 В°C) |
Hazardous environment | gas, dust, gas and dust |
Input IV | User interface module |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes |
Purge flow rate | Maximum flow rate measurement for enclosure size (enclosure volume:flow rate): < 20 ftВі (0.57mВі): 5, 12 SCFM (56, 141, 340 l/min), or dynamic 20 ... 30 ftВі (0.57 ... 0.85 mВі): 5, 12, 20 SCFM (56, 141, 340, 565 l/min), or dynamic > 30 ftВі (0.85mВі): 5, 12, 20, 30 SCFM (56, 141, 340, 565, 850 l/min), or dynamic |
Protective gas supply | instrument grade air or inert gas |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Purge flow and enclosure pressure rate | With EPV-6000-xx-01, EPV-6000-xx-02 5 SCFM @ 1.5"" wc, (141 l/min @ 3.7 mbar) 12 SCFM @ 2.0"" wc, (340 l/min @ 5.0 mbar) 20 SCFM @ 2.7"" wc, (565 l/min @ 6.7 mbar) 30 SCFM @ 4.1"" wc, (850 l/min @ 10.2 mbar) With EPV-6000-xx-03, EPV-6000-xx-04 5 SCFM @ 2.1"" wc, (141 l/min @ 5.2 mbar 12 SCFM @ 2.6"" wc, (340 l/min @ 6.5 mbar) 20 SCFM @ 4.1"" wc, (565 l/min @ 10.2 mbar) 30 SCFM @ 5.3"" wc, (850 l/min @ 13.2 mbar) With EPV-6000-xx-05, EPV-6000-xx-06 5 SCFM @ 1.8"" wc, (141 l/min @ 4.5 mbar) 12 SCFM @ 2.9"" wc, (340 l/min @ 7.3 mbar) 20 SCFM @ 7.4"" wc, (565 l/min @ 18.5 mbar) |