We ship to United States of America!
  • Certified for Class I, Class II, Division I- Zone 1 / Zone 21 to nonhazardous
  • Intrinsically safe electrical/pneumatic manifold assembly
  • Intrinsically safe user interface for programming and monitoring the system
  • Enclosure volume up to 450 ft3 (12.1 m3)
  • Control Unit monitors system operation and controls enclosure power
  • Universal mounting (brackets included)
  • 316L stainless steel Type 4X enclosure
Item Number: 6000 Control System
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +
IECEx UL 08.0003XClass I, Zone 1, Group IIC T4User interfacecULus
6000 Main control unit kit version
6000-xx-S2-UN-CK-xx:
cULus
Class I, Division 1, Groups A,B,C,D T4 (-20 В°C Ta 60 В°C)
Class II, Division 1, Groups E,F,G T4 (-20 В°C Ta 60 В°C)
Class I, Zone 1, Group IIC T4
Class II, Zone 21, Group IIIC T60 В°C
[Ex i] Associated Equipment
Ex db [ib pxb] IIC T4 X (-20 В°C Ta 60 В°C)
Ex db [ib pxb] IIIC T4 X (-20 В°C Ta 60 В°C)
6000 Main control unit kit version
6000-xx-S2-UN-CK-xx:
IECEx UL 08.0003X
Ex db [ib pxb] IIC T4 Gb (-20 В°C Ta 60 В°C)
Ex db [ib pxb] IIIC T80 В°C Db (-20 В°C Ta 60 В°C)Ex ib [pxb] IIC T4 GbEx i Intrinsically safe(-20 В°C Ta 60 В°C)Class I, Division 1, Groups A,B,C,D T46000-UIC-xx:6000-UIC-xx:User interface
MaterialEnclosure: 316L (UNS S31603) stainless steel
Manifold valve: anodized 6082 aluminum
Fittings: 316L (UNS S31603) stainless steel
Input IITemperature inputs
Rated voltage90 ... 264 V AC, 48 ... 62 Hz / 0.2 A
20 ... 30 V DC
Dimensions183 x 367.5 x 152.5 mm (7.20 x 14.45 x 6.00 inch)
ConnectionTerminal blocks
Input IInputs 1, 2, 3, 4: contact input, 5 VDC @ 2 mA
Output IAUX 1
Connection typePneumatic :
Inlet fitting to manifold: 3/8"" NPT (female)
Outlet fitting from manifold: 3/8"" bulkhead fitting (provided)
Storage temperature-30 ... 80 В°C (-22 ... 176 В°F)
Mass-WH- 11.4 kg (25 lb)
-CK- 7.2 kg (16 lb)
Pressure requirement20 ... 120 psig (1.4 ... 8.3 bar) (138 ... 827 kPa) regulated
Operating modemanual, semi-automatic, or fully automatic - programmable
Relative humidity5 ... 95 %, noncondensing
Output IIIENC_1, ENC_2 (protected enclosure contacts)
Degree of protectionType 4X , IP66
Number of volume exchanges4 to 19
Cable gland4 - M16 x 1.5 cable gland
Safe pressureGas: 0.25"" wc (6.4 mm wc) (0.625 mbar) (62 Pa)
Dust: 0.65"" wc (16.5 mm wc) (1.6 mbar) (162 Pa)
Gas and Dust: 0.65"" wc (16.5 mm wc) (1.6 mbar) ( 162 Pa)
Output IIAUX 2
IECEx approval6000 Main Control unit with housing
6000-xx-S2-UN-xx-xx:
IECEx UL 08.0003X
Ex db [ib pxb] IIC T4 Gb (-20 В°C Ta 60 В°C)
Ex db tb [ib pxb] IIIC T60 В°C Db (-20 В°C Ta 50 В°C)
Input IIIEPV-6000 Vent
LED indicatorSafe pressure: Blue - safe pressure is achieved
Enclosure power: Green - power on; Red - power off
Rapid exchange: Blue - purging is running
System bypass: Yellow - bypass is activated
Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - 6000 series system fault
Impact resistance30 g, 11 ms, all axes
Flow rate for leakage compensationDepends on enclosure seal.

With EPV-6000-xx-01, EPV-6000-xx-02
0.35 SCFM @ 0.25"" wc (10.0 l/min @ 6.3 mbar)
1.0 SCFM @ 0.75"" wc (28.0 l/min @ 1.9 mbar)

With EPV-6000-xx-03, EPV-6000-xx-04
0.22 SCFM @ 0.25"" wc (6.2 l/min @ 6.3 mbar)
0.58 SCFM @ 0.75"" wc (16.4 l/min @ 1.9 mbar)

With EPV-6000-xx-05, EPV-6000-xx-06
0.15 SCFM @ 0.25"" wc (4.2 l/min @ 6.3 mbar)
0.35 SCFM @ 0.75"" wc (10.0 l/min @ 1.9 mbar)
UL approval6000 Main control unit with housing
6000-xx-S2-UN-xx-xx:
cULus
Class I, Division 1, Groups A,B,C,D T4 (-20 В°C Ta 60 В°C)
Class II, Division 1, Groups E,F,G T4 (-20 В°C Ta 50 В°C)
Class I, Zone 1, Group IIC T4 (-20 В°C Ta 60 В°C)
Class II, Zone 21, Group IIIC T60 В°C (-20 В°C Ta 50 В°C)
[Ex i] Associated Equipment
Ex db [ib pxb] IIC T4 (-20 В°C Ta 60 В°C)
Ex db tb [ib pxb] IIIC T4 (-20 В°C Ta 50 В°C)
Hazardous environmentgas, dust, gas and dust
Input IVUser interface module
Vibration resistance5 ... 100 Hz , 1 g, 12 m/s2, all axes
Purge flow rateMaximum flow rate measurement for enclosure size (enclosure volume:flow rate):
< 20 ftВі (0.57mВі): 5, 12 SCFM (56, 141, 340 l/min), or dynamic
20 ... 30 ftВі (0.57 ... 0.85 mВі): 5, 12, 20 SCFM (56, 141, 340, 565 l/min), or dynamic
> 30 ftВі (0.85mВі): 5, 12, 20, 30 SCFM (56, 141, 340, 565, 850 l/min), or dynamic
Protective gas supplyinstrument grade air or inert gas
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Purge flow and enclosure pressure rateWith EPV-6000-xx-01, EPV-6000-xx-02
5 SCFM @ 1.5"" wc, (141 l/min @ 3.7 mbar)
12 SCFM @ 2.0"" wc, (340 l/min @ 5.0 mbar)
20 SCFM @ 2.7"" wc, (565 l/min @ 6.7 mbar)
30 SCFM @ 4.1"" wc, (850 l/min @ 10.2 mbar)

With EPV-6000-xx-03, EPV-6000-xx-04
5 SCFM @ 2.1"" wc, (141 l/min @ 5.2 mbar
12 SCFM @ 2.6"" wc, (340 l/min @ 6.5 mbar)
20 SCFM @ 4.1"" wc, (565 l/min @ 10.2 mbar)
30 SCFM @ 5.3"" wc, (850 l/min @ 13.2 mbar)

With EPV-6000-xx-05, EPV-6000-xx-06
5 SCFM @ 1.8"" wc, (141 l/min @ 4.5 mbar)
12 SCFM @ 2.9"" wc, (340 l/min @ 7.3 mbar)
20 SCFM @ 7.4"" wc, (565 l/min @ 18.5 mbar)