Pepperl+Fuchs 6500-01-*-PNO-LNO
6500 Control Unit
- Automatic purge and pressurization system for most applications
- User-friendly, easy programming
- LCD screen for operation status and LED's for quick visual identification of system
- HART communication through RS485 with PACTware and device app's through Bluetooth
- Maximum enclosure size 12.75 cubic meters
- Compact design with panel mounts or direct mounts available
- Universal power 20 to 30 VDC / 100 to 250 VAC. 50 to 60 HZ
- Pressure, temperature, dilution control and monitoring
- Up to SIL 2 acc. to IEC 61508
- Overview
- Comments
Degree of protection | IP66 |
Output III | Digital valve When used with the 6500-MAN-DV-01, intrinsically safe Internal resistance 280 andOmega; |
IECEx approval | IECEx UL / DEMKO 15.0147X |
Relative humidity | 5 ... 85 %, non-condensing |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Safety Integrity Level (SIL) | SIL 2 |
Mass | approx. 5 kg (11.0 lbs) |
Hazardous environment | gas, dust, gas and dust |
Impact resistance | 30 g, 11 ms, all axes |
Display elements | 2x20 LCD for configuration, monitoring, and status of the 65000 system with back light and contrast selection. Capacitive touch buttons |
Input II | (1) 2-wire, PT100 RTD |
Pressure requirement | For 6500-MAN-DV: 1.4 to 8.3 bar (20 to 120psig) regulated For 6500-MAN-PV: 3.5 to 6.9 bar (50 to 100 psig) regulated Note: max. pressure will depend on the vent model used. regulated |
Connection | EPCU: Terminal blocks and grounding screw UIC: 4-pin conncector and cable (provided), for the 6500-01-PM02, cable length is 5 meters Input type: intrinsically safe |
Operating mode | user programmable |
Output IV | Proportional valve When used with the 6500-MAN-PV-01, intrinsically safe Current: 4 to 20 mA Max. load: 300 andOmega; |
Connection type | See mounting in 6500 manual and cable gland requirements |
Input I | Voltage free contact or namur proximity sensor |
Ambient temperature | -20 ... 70 В°C (-4 ... 158 В°F) |
Communication | HART via RS485 (PACTware available) |
Rated voltage | 100 ... 240 V AC, 48 ... 62 Hz / 0.2 A 20 ... 30 V DC |
Cable gland | Cable gland requirement: cable glands are not included. Customer can supply there own approved glands or use one of the 6500-CBLG-... cable gland kits. I.S.cable glands: requires (5) M12 approved cable glands Power cable glands: requires (2) m20 and (2) M12 approved cable glands |
Number of volume exchanges | 5 to 19 |
Material | UIC display: Makrolon FI cover and A380 Aluminum anodized casing Housing: 316L stainless steel Hardware: 316L stainless steel |
EU-Type Examination Certificate | ATEX UL / DEMKO 15 ATEX 1622X |
Output I | AUX |
Dimensions | 6500-01-EXT1: 150 x 150 x 145 mm (5.9"" x 5.9"" x 5.7"") 6500-01-PM01: 150 x 150 x 185 mm (5.9"" x 5.9"" x 7.3"") 6500-01-PM02: EPCU: 150 x 150 x 145 mm (5.9"" x 5.9"" x 5.7""), UIC: 150 x 150 x 45 mm (5.9"" x 5.9"" x 1.8"") |
LED indicator | Safe pressure: Blue - safe pressure is achieved Enclosure power: Green - power on; Red - power off Rapid exchange: Blue - purging is running System bypass: Yellow - bypass is activated Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - 6000 series system fault Key: green - a button on the capacitive touch display has been activated. Momentary indication |
Valve flows | Standard vent series: EPV-6500-*-01, 03, 05 Readout on display is from 56 to 850 l/min (2 to 30 scfm) in increments of 28l/min (1 scfm). Minimum and maximum reading depending on type of vent and supply pressure. See data sheet for EPV-6500 series vent. |
Series | 6500 |
Protective gas supply | instrument grade air or inert gas |
Storage temperature | -40 ... 70 В°C (-40 ... 158 В°F) |
Safe pressure | Gas: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa) Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa) Gas+Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa) |
Output II | Enclosure |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes |
People also buy
Comments
No comments yet