Pepperl+Fuchs 6500-01-EXT1-PNO-LNO art 516124
6500 Control Unit
- Automatic purge and pressurization system for most applications
- Universal power 20 to 30 VDC / 100 to 250 VAC. 50 to 60 HZ
- Up to SIL 2 acc. to IEC 61508
- Overview +
- Comments +
Degree of protectionIP66Continuous (Dilution) vent series: EPV-6500-*-07, 08Readout on display is from 17 to 226 l/min (0.6 to 8 scfm) continuous reading.Maximum reading depending on type of vent and supply pressure.See data sheet for EPV-6500 series vent.
Features:
- Compact design with panel or direct mounts available
- Universal power supply from 20 to 30 V DC / from 100 to 250 V AC. 50 to 60 Hz
- Pressure, temperature, dilution and control
- Convenient, easy programming
- LCD screens for operating status and LEDs for quick visual system identification
- HART communication via RS485 with PACTware and device application via bluetooth
- The maximum body size is 12.75 cubic meters.
6500-01-EXT1-PNO-LNO Datasheet:
- Relative humidity: 5 ... 85 %, non-condensing
- Safety Integrity Level (SIL): SIL 2
- Mass: approx. 5 kg (11.0 lbs)
- Hazardous environment: gas, dust, gas and dust
- Impact resistance: 30 g, 11 ms, all axes
- Display elements: 2x20 LCD for configuration, monitoring, and status of the 65000 system with back light and contrast selection. Capacitive touch buttons
- Input II: (1) 2-wire, PT100 RTD
- Pressure requirement: For 6500-MAN-DV: 1.4 to 8.3 bar (20 to 120psig) regulated
- For 6500-MAN-PV: 3.5 to 6.9 bar (50 to 100 psig) regulated
- Note: max. pressure will depend on the vent model used. regulated
- Connection EPCU: Terminal blocks and grounding screw
- UIC: 4-pin conncector and cable (provided), for the 6500-01-PM02, cable length is 5 meters
- Input type: intrinsically safe
- Operating mode: user programmable
- Output IV: Proportional valve
- When used with the 6500-MAN-PV-01, intrinsically safe
- Current: 4 to 20 mA
- Max. load: 300 andOmega;
- Connection type: See mounting in 6500 manual and cable gland requirements
- Input I Voltage free contact or namur proximity sensor
- Ambient temperature: -20 ... 70 В°C (-4 ... 158 В°F)
- Communication: HART via RS485 (PACTware available)
- Rated voltage: 100 ... 240 V AC, 48 ... 62 Hz / 0.2 A 20 ... 30 V DC
- Cable gland: Cable gland requirement: cable glands are not included. Customer can supply there own approved glands or use one of the 6500-CBLG-... cable gland kits.
- I.S.cable glands: requires (5) M12 approved cable glands
- Power cable glands: requires (2) m20 and (2) M12 approved cable glands
- Number of volume exchanges: 5 to 19
- Material UIC display: Makrolon FI cover and A380 Aluminum anodized casing
- Housing: 316L stainless steel
- Hardware: 316L stainless steel
- LED indicator Safe pressure: Blue - safe pressure is achieved
- Enclosure power: Green - power on; Red - power off
- Rapid exchange: Blue - purging is running
- System bypass: Yellow - bypass is activated
- Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - 6000 series system fault
- Key: green - a button on the capacitive touch display has been activated. Momentary indication
- Valve flows Standard vent series: EPV-6500-*-01, 03, 05
- Readout on display is from 56 to 850 l/min (2 to 30 scfm) in increments of 28l/min (1 scfm).
- Minimum and maximum reading depending on type of vent and supply pressure.
- Series 6500 Protective gas supply instrument grade air or inert gas
- Storage temperature: -40 ... 70 В°C (-40 ... 158 В°F)
- Safe pressure: Gas: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
- Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
- Gas+Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Buy Pepperl+Fuchs 6500-01-EXT1-PNO-LNO art 516124 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. offers factory automation products. You can find a huge online catalog of automation equipment on our website. We provide super fast delivery to any country. Get the exclusive offer, contact us now! We strive to deliver your order on time, following our obligations. We are constantly developing to satisfy all your needs in electrical equipment supply.
Comments
No comments yet