Pepperl+Fuchs 6500-01-EXT1-PNO-LNO art 516124
6500 Control Unit
- Automatic purge and pressurization system for most applications
- Universal power 20 to 30 VDC / 100 to 250 VAC. 50 to 60 HZ
- Up to SIL 2 acc. to IEC 61508
- Overview
- Comments
Degree of protectionIP66Continuous (Dilution) vent series: EPV-6500-*-07, 08Readout on display is from 17 to 226 l/min (0.6 to 8 scfm) continuous reading.Maximum reading depending on type of vent and supply pressure.See data sheet for EPV-6500 series vent.
Features:
- Compact design with panel or direct mounts available
- Universal power supply from 20 to 30 V DC / from 100 to 250 V AC. 50 to 60 Hz
- Pressure, temperature, dilution and control
- Convenient, easy programming
- LCD screens for operating status and LEDs for quick visual system identification
- HART communication via RS485 with PACTware and device application via bluetooth
- The maximum body size is 12.75 cubic meters.
6500-01-EXT1-PNO-LNO Datasheet:
- Relative humidity: 5 ... 85 %, non-condensing
- Safety Integrity Level (SIL): SIL 2
- Mass: approx. 5 kg (11.0 lbs)
- Hazardous environment: gas, dust, gas and dust
- Impact resistance: 30 g, 11 ms, all axes
- Display elements: 2x20 LCD for configuration, monitoring, and status of the 65000 system with back light and contrast selection. Capacitive touch buttons
- Input II: (1) 2-wire, PT100 RTD
- Pressure requirement: For 6500-MAN-DV: 1.4 to 8.3 bar (20 to 120psig) regulated
- For 6500-MAN-PV: 3.5 to 6.9 bar (50 to 100 psig) regulated
- Note: max. pressure will depend on the vent model used. regulated
- Connection EPCU: Terminal blocks and grounding screw
- UIC: 4-pin conncector and cable (provided), for the 6500-01-PM02, cable length is 5 meters
- Input type: intrinsically safe
- Operating mode: user programmable
- Output IV: Proportional valve
- When used with the 6500-MAN-PV-01, intrinsically safe
- Current: 4 to 20 mA
- Max. load: 300 andOmega;
- Connection type: See mounting in 6500 manual and cable gland requirements
- Input I Voltage free contact or namur proximity sensor
- Ambient temperature: -20 ... 70 В°C (-4 ... 158 В°F)
- Communication: HART via RS485 (PACTware available)
- Rated voltage: 100 ... 240 V AC, 48 ... 62 Hz / 0.2 A 20 ... 30 V DC
- Cable gland: Cable gland requirement: cable glands are not included. Customer can supply there own approved glands or use one of the 6500-CBLG-... cable gland kits.
- I.S.cable glands: requires (5) M12 approved cable glands
- Power cable glands: requires (2) m20 and (2) M12 approved cable glands
- Number of volume exchanges: 5 to 19
- Material UIC display: Makrolon FI cover and A380 Aluminum anodized casing
- Housing: 316L stainless steel
- Hardware: 316L stainless steel
- LED indicator Safe pressure: Blue - safe pressure is achieved
- Enclosure power: Green - power on; Red - power off
- Rapid exchange: Blue - purging is running
- System bypass: Yellow - bypass is activated
- Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - 6000 series system fault
- Key: green - a button on the capacitive touch display has been activated. Momentary indication
- Valve flows Standard vent series: EPV-6500-*-01, 03, 05
- Readout on display is from 56 to 850 l/min (2 to 30 scfm) in increments of 28l/min (1 scfm).
- Minimum and maximum reading depending on type of vent and supply pressure.
- Series 6500 Protective gas supply instrument grade air or inert gas
- Storage temperature: -40 ... 70 В°C (-40 ... 158 В°F)
- Safe pressure: Gas: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
- Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
- Gas+Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)