Pepperl+Fuchs 6500-01-EXT1-PNO-LNO art 516124
6500 Control Unit

Pepperl+Fuchs 6500-01-EXT1-PNO-LNO art 516124
  • Automatic purge and pressurization system for most applications
  • Universal power 20 to 30 VDC / 100 to 250 VAC. 50 to 60 HZ
  • Up to SIL 2 acc. to IEC 61508
Item Number: 6500-01-EXT1-PNO-LNO art 516124
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Degree of protectionIP66Continuous (Dilution) vent series: EPV-6500-*-07, 08Readout on display is from 17 to 226 l/min (0.6 to 8 scfm) continuous reading.Maximum reading depending on type of vent and supply pressure.See data sheet for EPV-6500 series vent.

Features:

  • Compact design with panel or direct mounts available
  • Universal power supply from 20 to 30 V DC / from 100 to 250 V AC. 50 to 60 Hz
  • Pressure, temperature, dilution and control
  • Convenient, easy programming
  • LCD screens for operating status and LEDs for quick visual system identification
  • HART communication via RS485 with PACTware and device application via bluetooth
  • The maximum body size is 12.75 cubic meters.

6500-01-EXT1-PNO-LNO Datasheet:

  • Relative humidity: 5 ... 85 %, non-condensing
  • Safety Integrity Level (SIL): SIL 2
  • Mass: approx. 5 kg (11.0 lbs)
  • Hazardous environment: gas, dust, gas and dust
  • Impact resistance: 30 g, 11 ms, all axes
  • Display elements: 2x20 LCD for configuration, monitoring, and status of the 65000 system with back light and contrast selection. Capacitive touch buttons
  • Input II: (1) 2-wire, PT100 RTD
  • Pressure requirement: For 6500-MAN-DV: 1.4 to 8.3 bar (20 to 120psig) regulated
  • For 6500-MAN-PV: 3.5 to 6.9 bar (50 to 100 psig) regulated
  • Note: max. pressure will depend on the vent model used. regulated
  • Connection EPCU: Terminal blocks and grounding screw
  • UIC: 4-pin conncector and cable (provided), for the 6500-01-PM02, cable length is 5 meters
  • Input type: intrinsically safe
  • Operating mode: user programmable
  • Output IV: Proportional valve
  • When used with the 6500-MAN-PV-01, intrinsically safe
  • Current: 4 to 20 mA
  • Max. load: 300 andOmega;
  • Connection type: See mounting in 6500 manual and cable gland requirements
  • Input I    Voltage free contact or namur proximity sensor
  • Ambient temperature: -20 ... 70 В°C (-4 ... 158 В°F)
  • Communication: HART via RS485 (PACTware available)
  • Rated voltage: 100 ... 240 V AC, 48 ... 62 Hz / 0.2 A 20 ... 30 V DC
  • Cable gland: Cable gland requirement: cable glands are not included. Customer can supply there own approved glands or use one of the 6500-CBLG-... cable gland kits.
  • I.S.cable glands: requires (5) M12 approved cable glands
  • Power cable glands: requires (2) m20 and (2) M12 approved cable glands
  • Number of volume exchanges: 5 to 19
  • Material UIC display: Makrolon FI cover and A380 Aluminum anodized casing
  • Housing: 316L stainless steel
  • Hardware: 316L stainless steel
  • LED indicator Safe pressure: Blue - safe pressure is achieved
  • Enclosure power: Green - power on; Red - power off
  • Rapid exchange: Blue - purging is running
  • System bypass: Yellow - bypass is activated
  • Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - 6000 series system fault
  • Key: green - a button on the capacitive touch display has been activated. Momentary indication
  • Valve flows Standard vent series: EPV-6500-*-01, 03, 05
  • Readout on display is from 56 to 850 l/min (2 to 30 scfm) in increments of 28l/min (1 scfm).
  • Minimum and maximum reading depending on type of vent and supply pressure.
  • Series    6500 Protective gas supply instrument grade air or inert gas    
  • Storage temperature: -40 ... 70 В°C (-40 ... 158 В°F)    
  • Safe pressure: Gas: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
  • Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
  • Gas+Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)