Pepperl+Fuchs CJ1-12GK-N-15M
Capacitive sensor

Pepperl+Fuchs CJ1-12GK-N-15M
  • Comfort series
Item Number: CJ1-12GK-N-15M
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Sensing facePBT
CE marking[*PD-Z02585A*]
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Output type2-wire
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Switching frequency0 ... 1 Hz
Highest permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Core cross-section0.34 mm2
CE marking[*PD-Z02585A*]
Assured operating distance0 ... 0.72 mm
CCC approvalCCC approval / marking not required for products rated 36 V
CSA approvalcCSAus Listed, General Purpose
Switching functionNormally open (NO)
Use in the hazardous areasee instruction manuals
ATEX marking II 1D Ex ia IIIC T135В°C Da
The Ex-related marking can also be printed on the enclosed label.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
Housing materialPBT
Effective internal capacitancemax. 60 nF ; a cable length of 10 m is considered.
Effective internal inductancenegligibly small
A cable length of 10 m is considered.
Rated operating distance1 mm
Connection typecable PVC , 15 m
Effective internal inductancenegligibly small
A cable length of 10 m is considered.
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
ATEX marking II 1G Ex ia IIC T6andhellip;T1 Ga
The Ex-related marking can also be printed on the enclosed label.
Operating voltage7 ... 12 V
Installationnon-flush
CE marking[*PD-Z02585A*]
Appropriate typeCJ1-12GK-N...
Output typeNAMUR
Appropriate typeCJ1-12GK-N...
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Appropriate typeCJ1-12GK-N...
Effective internal capacitancemax. 60 nF ; a cable length of 10 m is considered.
UL approvalcULus Listed, General Purpose
ATEX marking II 1G Ex ia IIC T6andhellip;T1 Ga
The Ex-related marking can also be printed on the enclosed label.
Effective internal inductancenegligibly small
A cable length of 10 m is considered.
Effective internal capacitancemax. 60 nF ; a cable length of 10 m is considered.
Degree of protectionIP68
Nominal voltage8 V