Pepperl+Fuchs CJ4-12GK-N-Y235563
Capacitive sensor
- 4 mm non-flush
- Custom cable length
- Customer specific connector
- Overview
- Comments
Nominal voltage | 8.2 V (Ri approx. 1 kandOmega;) |
Output type | 2-wire |
Effective internal inductance | negligibly small A cable length of 10 m is considered. |
Output type | NAMUR |
Effective internal capacitance | max. 60 nF ; a cable length of 10 m is considered. |
Appropriate type | CJ4-12GK-N... |
ATEX marking | II 1D Ex ia IIIC T135В°C Da The Ex-related marking can also be printed on the enclosed label. |
Operating voltage | 7 ... 12 V |
CE marking | [*PD-Z02585A*] |
Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
ATEX marking | II 1G Ex ia IIC T6andhellip;T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Supplementary information | Note! When making the electrical connection, ensure that the sensor cable is protected against mechanical stress! |
Effective internal capacitance | max. 60 nF ; a cable length of 10 m is considered. |
Core cross-section | 0.34 mm2 |
Assured operating distance | 0 ... 2.88 mm |
Switching frequency | 0 ... 1 Hz |
CE marking | [*PD-Z02585A*] |
Effective internal capacitance | max. 60 nF ; a cable length of 10 m is considered. |
Degree of protection | IP68 |
CCC approval | CCC approval / marking not required for products rated 36 V |
CE marking | [*PD-Z02585A*] |
CSA approval | cCSAus Listed, General Purpose |
Effective internal inductance | negligibly small A cable length of 10 m is considered. |
Sensing face | PBT |
ATEX marking | II 1G Ex ia IIC T6andhellip;T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Installation | non-flush |
Use in the hazardous area | see instruction manuals |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
UL approval | cULus Listed, General Purpose |
Connection type | cable PVC , 55 mm with Connector, 99-3431-216-04, Binder |
Appropriate type | CJ4-12GK-N... |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Rated operating distance | 4 mm |
Appropriate type | CJ4-12GK-N... |
Switching function | Normally open (NO) |
Housing material | PBT |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Effective internal inductance | negligibly small A cable length of 10 m is considered. |
People also buy
Comments
No comments yet