Pepperl+Fuchs EPV-6500-*-*
EPV 6500 vent

Pepperl+Fuchs EPV-6500-*-*
  • A selection of vents for specific applications
  • Intrinsically safe operation
  • Continuous flow vents for precise flow rates for dilution applications
  • Continuous flow outputs for dilution, purging, and pressurization
  • Low leakage rate vents for air or inert gas conversation
  • High flow rate vents for fast, large enclosure systems
  • Universal mounting in any orientation including most of the unit inside the enclosure
  • Maximum enclosure size 12.75 cu.meters (450 cu.ft.)
  • ATEX/IECEx, Zone 1/21 certified for ""pyb"" and ""pxb""
  • Up to SIL 2 acc. to IEC 61508
Item Number: EPV-6500-*-*
1453.11
-
+
Total price: 1453.11
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Purge flow rateSee graphs
Readout on display is in increments of 28 l/min (1 scfm).
Minimum and maximum reading depends on type of vent and supply pressure.
EPV-6500-*-07, 08 will readout continuous flow.
Breaking pressureEPV-6500-...-01: 2.0 mbar (0.8"" wc)
EPV-6500-...-03: 3.5 mbar (1.4"" wc)
EPV-6500-...-05: 3.8 mbar (1.5"" wc)
EPV-6500-...-07: n/a
EPV-6500-...-08: n/a
Number of volume exchanges5 to 19
LED indicatorPOWER: green
Vibration resistance5 ... 100 Hz , 1 g, 12 m/s2, all axes
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
EU-Type Examination CertificateATEX UL / DEMKO 15 ATEX 1622X
Dimensions127 x 146 x 83 mm (5.0"" x 5.8"" x 3.3"")
Relative humidity5 ... 90 %, non-condensing
Shock resistanceEN 60068-2
Maximum pressuredepends on the integrity of the enclosure (strength)
max. vent pressure: 25'' wc (635 mm wc) (62 mbar / 6200 pa)
vent pressure range: 0 to 9.9"" wc (0 to 25 mbar)
Massapprox. 1.4 kg (3.1 lb)
Degree of protectionIP66
Cable lengthmax. 60 meters at 50 pf/ft and 0.2 ВµH/ft
Impact resistance30 g, 11 ms, all axes
Ambient temperature-20 ... 70 В°C (-4 ... 158 В°F)
Purge flow and enclosure pressure rateSee graphs
Readout on display is in increments of 28 l/min (1 scfm).
Minimum and maximum reading depends on type of vent and supply pressure.
EPV-6500-*-07, 08 will readout continuous flow.
Flow rate for leakage compensationEPV-6500....-01:
593 l/hr (21 scfh) @ .63mbar (.25""wc)
1640 l/hr (58 scfh) @ 1.9mbar (0.75""wc)
EPV-6500....-03:
395 l/hr (14 scfh) @ .63mbar (.25""wc)
961 l/hr (34 scfh) @ 1.9mbar (0.75""wc)
EPV-6500....-05:
260 l/hr (9.2 scfh) @ .63mbar (.25""wc)
622 l/hr (22 scfh) @ 1.9mbar (0.75""wc)
EPV-6500....-07: n/a
EPV-6500....-08: n/a
IECEx approvalIECEx UL / DEMKO 15.0147X

Installation- any orientation to enclosure
- not gravity dependent
- internal and external mounting possible
Safety Integrity Level (SIL)SIL 2
Hazardous environmentgas, dust, gas and dust
Series6500
Mounting1 ВЅ"" NPT knockout (50.8mm (2"") hole) with seal nut included
Degree of protectionEN 60529
Safe pressureGas: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Gas+Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Protective gas supplyinstrument grade air or inert gas

Comments

No comments yet

Write a comment