Pepperl+Fuchs FB3205B2
HART Transmitter Power Supply, Input Isolator

Pepperl+Fuchs FB3205B2
  • 4-channel
  • Inputs Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Power supply for 2-wire transmitters with 4 mA ... 20 mA
  • Supply circuit 15 V (20 mA)
  • Input from active signals of 4-wire transmitters
  • HART communication via field bus or service bus
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring
Item Number: FB3205B2
1132.04
-
+
Total price: 1132.04
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Connectionbackplane bus3-wire transmitter:Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-Supply circuit: channel I 1+, 4-, channel II 5+, 8-, channel III 9+, 12-, channel IV 13+, 16-Supply circuit: channel I 1+, 2-, channel II 5+, 6-, channel III 9+, 10-, channel IV 13+, 14-4-wire transmitter (powered externally):Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-

HART communicationyes
ATEX approvalBVS 12 ATEX E 101 X
HART secondary variableno
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
INMETROBrazil: TГњV 14.1597XSupplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration toolAmbient temperature-20 ... 60 В°C (-4 ... 140 В°F)LED indicationPower LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (1-4) red: line fault (lead breakage or short circuit)
Refresh time100 msCodingoptional mechanical coding via front socketDegree of protectionIP20 (module) , a separate housing is required acc. to the system descriptionMassapprox. 750 gShock resistanceEN 60068-2-27:2009Relative humidityEN 60068-2-78:2001Environmental testEN 60068-2-14:2009Degree of protectionIEC 60529:2000Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)Damaging gasEN 60068-2-42:2003Electromagnetic compatibilityNE 21:2007Conversion timemax. 100 msShock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18EU-Type Examination CertificateBVS 12 ATEX E 101 XOccupied slots2Vibration resistanceEN 60068-2-6:2008Interfacemanufacturer-specific bus to standard com unitPower dissipation1.5 WTransmitter supply voltagemin. 15 V at 20 mA ; 21.5 V at 4 mAConnection2-wire transmitter (HART):Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3Connectionbackplane busRelative humidity95 % non-condensingResolution12 Bit (0 ... 26 mA)Number of channels4Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Rated voltage12 V DC , only in connection with the power supplies FB92**Power consumption2.7 WInput resistance15 Ω