Pepperl+Fuchs FB3205B3
HART Transmitter Power Supply, Input Isolator

Pepperl+Fuchs FB3205B3
  • 4-channel
  • Inputs Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Power supply for 2-wire transmitters with 4 mA ... 20 mA
  • Supply circuit 15 V (20 mA)
  • Input from active signals of 4-wire transmitters
  • HART communication via field bus or service bus
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring
Item Number: FB3205B3
1132.04
-
+
Total price: 1132.04
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
3-wire transmitter:Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-Supply circuit: channel I 1+, 2-, channel II 5+, 6-, channel III 9+, 10-, channel IV 13+, 14-4-wire transmitter (powered externally):Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-Supply circuit: channel I 1+, 4-, channel II 5+, 8-, channel III 9+, 12-, channel IV 13+, 16-
Power consumption2.7 W
Transmitter supply voltagemin. 15 V at 20 mA ; 21.5 V at 4 mA
Connectionbackplane bus
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
IECEx approvalIECEx PRE 19.0011U
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
LED indicationPower LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (1-4) red: line fault (lead breakage or short circuit)
Relative humidityEN 60068-2-78:2001
Connectionbackplane bus
Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Electromagnetic compatibilityNE 21:2007
HART secondary variableno
Environmental testEN 60068-2-14:2009
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
Conversion timemax. 100 ms
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Damaging gasEN 60068-2-42:2003
Resolution12 Bit (0 ... 26 mA)
Shock resistanceEN 60068-2-27:2009
Number of channels4
Power dissipation1.5 W
Vibration resistanceEN 60068-2-6:2008
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Input resistance15 Ω
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Interfacemanufacturer-specific bus to standard com unit
HART communicationyes
Degree of protectionIEC 60529:2000
Occupied slots2
Codingoptional mechanical coding via front socket
Massapprox. 955 g
EU-Type Examination CertificatePresafe 19 ATEX 14056U
ATEX approvalPresafe 19 ATEX 14056U
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Rated voltage12 V DC , only in connection with the power supplies FB92**
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Relative humidity95 % non-condensing
Refresh time100 ms
Connection2-wire transmitter (HART):