Pepperl+Fuchs FB5204B
RTD Converter

Pepperl+Fuchs FB5204B
  • 4-channel
  • Inputs Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Converter for 2-, 3- and 4-wire RTDs (Pt100 ... Pt1000), slide wire sensors etc.
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring
Item Number: FB5204B
879.33
-
+
Total price: 879.33
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Number of channels4
ATEX approvalPTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U
Shock resistanceEN 60068-2-27
LED indicationLED green: supply
LED red: line fault, collective alarm , flashing: communication error
Massapprox. 750 g
Conversion timemax. 500 ms (4 channels)
max. 1 s (for 4x 3-wire Pt100)
Relative humidity95 % non-condensing
Measuring current200 andmicro;A
EU-Type Examination CertificatePTB 97 ATEX 1074 U
Degree of protectionIEC 60529
Slide-wire sensor0 ... 10 kandOmega;
Damaging gasEN 60068-2-42
EAC approvalRussia: RU C-IT.MIII06.B.00129
Occupied slots2
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Electromagnetic compatibilityNE 21
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Measurement rangePt100 (18-390 andOmega;) (500 andOmega; incl. line resistance)
Pt200 (37-780 andOmega;)
Pt500 (92-1952 andOmega;)
Pt1000 (185-3905 andOmega;)
Ni100 (69-270 andOmega;)
Ni500 (345-1350 andOmega;)
Ni1000 (690-2700 andOmega;)
Busy after download5 ... 15 s
Smallest span50 andOmega; for 0.1 % accuracy
Interfacemanufacturer-specific bus to standard com unit
Lead resistancemax. 50 andOmega; per strand
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Linearity error0.1 %
Line fault detectioncan be switched on/off for each channel via configuration tool
Power dissipation0.35 W
Connectionbackplane bus
Vibration resistanceEN 60068-2-6
Codingoptional mechanical coding via front socket
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies FB92**
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Relative humidityEN 60068-2-56
Power consumption0.35 W
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Environmental testEN 60068-2-14
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)
Connectionchannel I: resistance/potentiometer input 1 ... 4
channel II: resistance/potentiometer input 5 ... 8
channel III: resistance/potentiometer input 9 ... 12
channel IV: resistance/potentiometer input 13 ... 16

Comments

No comments yet

Write a comment